Technical Data - Gira TeleCoppler 2 Operating Instructions Manual

Alarming and remote switching device
Table of Contents

Advertisement

10

Technical Data

Dimensions
L x W x H (in mm):
Weight:
Color:
Material:
Temperature
Operation temperature:
Storage temperature:
Protection class:
Plug power supply
Weight:
Input voltage
Input:
Output:
Length of power supply cord:
Protection class:
Class:
Outputs
6 conventionel outputs:
1 local alarm output:
(all short circuit proof and
surged with 200 mA)
General capacity of the
switching outputs:
Current consumption of the
TeleCoppler 2
all outputs in idle mode
Current:
Voltage:
Power consumption:
all outputs with full load
Current:
Voltage:
Power consumption:
Inputs
6 conventional inputs:
Telephone connections
Analog:
Length of subscriber line:
RS 232
Length of the Telephone cord
RS 232:
* using the plug power supply
251 x 204 x 49
700 g
RAL 7035
ABS
-5 °C to 45 °C
-25 °C to 70 °C
IP30 according to EN 60529
160 g
100-240 V AC, 47-63 Hz, 400 mA
12 V DC, 1.25 A
2 m
IP41 according to EN 60529
II according to EN 60536
12 V DC, 100 mA*
12 V DC, 100 mA*
< 700 mA
150 mA
12 V
1.8 W
850 mA (TeleCoppler 2 idle mode+6 convent. outputs+1 loc.
alarm)
12 V
10.2 W
for potential free contacts (activation time > 50 ms)
CTR 21
each 3 m
3 m
Subjected to technical changes.
10 Technical Data