Battery Installation

The Lyric Gateway is equipped with an integral, replaceable, rechargeable battery pack rated at 7.2Vdc. In the
event of an AC power loss, the system is supported by the long life backup battery that is supervised for
connection and for low voltage conditions. If the battery is missing, or a low battery condition is detected, a
"low battery"
message is displayed on the smart device and "Alert" will flash red on the Gateway. In addition, a
System Low Battery
report is sent to the Central Station. In addition, the system will beep once every 45
seconds to audibly indicate a low battery condition (press any key to stop the beeping). Select the appropriate
battery pack, based on the installation's requirement, and install the battery pack. Follow the steps and refer to
the figure below to install and connect the battery.

Battery Selection

Select the appropriate battery pack, based on the installation's requirement, and install the battery pack.
Battery Part Number
300-03864-AIO
300-03866-AIO

Replacing the Rechargeable Backup Battery

1.
Insert the battery pack into gateway.
2.
Close the hinged battery retainer.
3.
Connect the battery pack connector to the receptacle on the gateway.
4.
Align the slots on the back of the controller with the hooks on the
5.
Once attached, insert the screw to secure the
6.
Plug the power supply into a 24-hour, 110VAC unswitched outlet. Upon power-up,
alternately.
7.
When the power-up sequence is complete, the green Disarmed LED and the green shield will be lit.
Rechargeable batteries may take up to 48-hours to fully charge. The "Low Battery" message
should clear within four hours or by entering Test Mode.
Replacing the Rechargeable Backup Battery
1.
When battery replacement is required, at the Master User Tools Menu screen select the "Advanced" icon.
2.
Select "Install Backup Battery" and follow the displayed steps to replace the battery or follow the steps
below.
Remove the battery
1.
Remove the screw securing the
2.
Remove the back case or remove the gateway from the rear cover/wall mount.
Battery StandbyTime
4-hours (minimum)
24-hours (minimum)
rear
cover/wall mount.
gateway to the rear
cover/wall mount (if used).
- 7 -
Lyric Controller Installation and Reference Guide
Installing the Gateway
Low Battery Notification
Approximately 1-hour before battery depletion
At least 1-hour before battery depletion
rear
cover/wall mount as shown below.
the LEDs will flash