Installing the Control

AC Power

The Lyric Gateway is powered by a 110VAC, 60 Hz/9 Volt DC, 2.5 Amp Plug-in Power Supply, 300-04705V1
(300-04063V1 in Canada). Refer to the wiring table below for wire gauge and length.
Use only the 300-04705V1 (300-04063V1 Canada) Power Supply. Do not plug the power supply
into the AC outlet until after all wiring connections have been made.

Wiring Overview

The following summarizes the electrical connections associated with the Lyric Gateway. Follow the steps and
refer to the figure below when making connections. Refer to the Summary of Connections diagram for
additional information.

Make Electrical Connections

1. Temporarily hang the controller from the hook on the wall mount.
2. Connect the male end of the receptacle on the Gateway.
3.
Align the slots on the back of the Gateway with the hooks on the rear cover/mounting bracket.
4.
Once attached, insert the screw to secure the Gateway to the rear cover/mounting bracket .
5.
Connect the flying leads of the provided power supply cable to the + and – terminals on the power supply
(p/n 300-04705V1 or 300-04063V1).
6.
Plug the power supply into a 24-hour, 110VAC unswitched outlet. Upon power-up, the "System Standby!"
screen will be displayed.
Maximum Distance Between
Power Supply and Controller
Up to 8 feet (2.44 m)
Up to 13 feet (3.96 m)
Up to 20 feet (6.1 m)
(Continued)
WIRING TABLE
Wire Gauge
# 22
# 20
# 18