Combining Continuous Access Xp And Volume Manager; Combining Continuous Access Xp And Custom Volume Size (Cvs); Combining Continuous Access Xp And Cache Lun Xp; Combining Continuous Access Xp And Lun Manager - HP StorageWorks XP12000 User Manual

Continuous access xp
Hide thumbs Also See for StorageWorks XP12000:
Table of Contents

Advertisement

NOTE:
If the license capacity for LUN Security XP Extension is insufficient in the disk array on the secondary site,
you might not be able to create Continuous Access XP pairs. For more information about the license
capacity for LUN Security XP Extension, see the

Combining Continuous Access XP and Volume Manager

LUSE volumes can be assigned to Continuous Access XP pairs, if the P-VOL and S-VOL have the same LU
type and number of LDEVs. To perform LUSE operations on an existing Continuous Access XP P-VOL
or S-VOL, delete the pair first to return the volume to SMPL status.
For more information about Volume Manager, see the HP StorageWorks LUN Configuration and Security
Manager XP user guide for the XP12000/XP10000.
NOTE:
If you allocate a LUSE volume consisting of LDEVs set across more than one CU to the Continuous Access
XP pair, you must select CU Free for an RCU (see
consisting of LDEVs set across more than one CU cannot create a pair with the volume of an XP12000
disk array because CU Free cannot be added as an RCU with the XP12000 and disk array.

Combining Continuous Access XP and Custom Volume Size (CVS)

Custom volumes can be assigned to Continuous Access XP pairs if the S-VOL has the same capacity as
the P-VOL. If you need to perform CVS operations on an existing Continuous Access XP P-VOL or S-VOL,
delete the pair first to return the volume to SMPL status.
NOTE:
For more information about Volume Manager, see the
Manager XP user guide for the XP12000/XP10000

Combining Continuous Access XP and Cache LUN XP

HP Cache LUN XP volumes can be assigned to Continuous Access XP pairs, and Cache LUN XP
operations can be performed on Continuous Access XP P-VOLs and S-VOLs.
NOTE:
For more information about Cache LUN XP, see the
for the XP12000/XP10000

Combining Continuous Access XP and LUN Manager

LUN Manager operations do not affect Continuous Access XP operations. Volumes under secure ports
and/or assigned to host groups or iSCSI targets can also be assigned to Continuous Access XP pairs.
Volumes assigned to Continuous Access XP pairs can also be assigned to secure ports, host groups, or
iSCSI targets for LUN Manager.
For more information about LUN Manager, see the HP StorageWorks LUN Configuration and Security
Manager XP user guide for the XP12000/XP10000.
52
Continuous Access XP for the Array
HP StorageWorks LUN Security XP Extension user guide
Registering RCUs (Add
.
.
RCU)). The LUSE volume
HP StorageWorks LUN Configuration and Security
HP StorageWorks Cache LUN XP user guide
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp10000Storageworks svs200

Table of Contents