Dc Motor Blocked - Haier AV08NMSETA Service Manual

Table of Contents

Advertisement

[71] DC motor blocked

PCB connection is well
Forced the fan in low speed,
measure if it has alternating
voltage between FG and GND
Replace the outdoor PCB
Rotate fan motor by
hand to check if there
is obviously fiction
No
Check the motor and
Yes
Yes
Yes
Replace fan motor
No
No
Replace the motor
68
68
Re-connect