Omega OM-DLAV Instructions Manual

Ac voltage data logger

Advertisement

Quick Links

AC Voltage Data Logger
1

Advertisement

Table of Contents
loading

Summary of Contents for Omega OM-DLAV

  • Page 1 AC Voltage Data Logger...
  • Page 2: Om-Dlav Data Logger Instructions

    Plotter. This interval can be set from 5 seconds to 60 minutes. A user message of up to 20 characters can also be stored in the OM-DLAV. This message can be used to identify a customer’s location or identify a particular logger for tracking purposes.
  • Page 3 Refer to the owner’s manual for your computer to find instructions on setting the PC time if it is not correct. 8. When all of the settings for the OM-DLAV are to your satisfaction, click on OK to store the setting in the OM-DLAV and to close the window.
  • Page 4: T O Start A Recording

    AC Voltage Data Logger 10. You can now connect a different OM-DLAV or exit the program. To exit the program, click on the Exit button on the tool bar. TART A ECORDING To begin a new recording slide the access door closed. The LED indicator will begin to flash for 10 seconds.
  • Page 5: Connecting The Om-Dlav

    OM-DLAV ONNECTING THE Plug each clip lead firmly into the OM-DLAV. Make sure that there is no strain that could pull the clip leads out of the OM-DLAV socket. Connect the clip leads to the points that the voltage is being measured. Make sure that the leads will not interfere with any moving pieces of equipment and will not pull loose any wires or other connections.
  • Page 6: Viewing A Recording As A Graph

    AC Voltage Data Logger The program will begin to retrieve the recording. A status bar along the top of the window will show the progress of information being retrieved. When the information has been retrieved, the program will automatically dis- play the recording in the display mode that has been selected.
  • Page 7: View A Recording As Text

    AC Voltage Data Logger The enclosed area of the box will now be zoomed so that it fills the entire window. This may be repeated if additional magnification of an area of the graph is desired. To return to the original graph with no auto scaling, click on the Full Graph button.
  • Page 8: Data Logger Calibration

    New Password section. Click the OK button when finished. If this is the first time you are calibrating the OM-DLAV, no pass- word is needed. You can click the OK button or press the Enter key to continue.
  • Page 9: Battery Replacement

    The LED will stop flashing and the OM-DLAV will not allow a new record- ing to be started until the battery has been replaced. Recorded data can be re- trieved regardless of the condition of the battery.
  • Page 10: Om-Dlav Product Specifications

    AC Voltage Data Logger OM-DLAV P RODUCT PECIFICATIONS Ambient Operating Temperature +10°F to +150°F (-12°C to +65°C) Range Storage Temperature -40°F to +170°F (-40°C to +76°C) Time Accuracy +/- 100ppm @ 75°F Voltage Range 0 to 450 VAC Voltage Resolution 0.15VAC...