Problems With Configuration
If a configuration error appears and you have difficulty isolating the fault, you can reset all
configurable settings to default except for the time and date, password, BOOTP setting, and Telnet
timeout. You can then restart your configuration process. To update reset to default, follow these
steps:
1. At the Main menu, type
2. At the Utilities menu, type
the prompts on the screen.
3. To return to the Main Menu, press <Esc>.
SW2 (Software Control) Setting Ignored
If the 2346 was installed in a UCS 1000 or 1002 and set in the User Interface to software control, it
ignores the line buildout switch setting when placed in a UCS 1001 or Model 1030. For details on
setting the 2346 to hardware control before installing, see Chapter 2.
Problems With Fiber Optics
If the CLS LED lights Red or the System Alarms screen shows a Fiber Loss of Signal, inspect and
clean the cables and connectors, then replace any damaged fiber. Retest the 2346 after cleaning.
PING
Use the PING Generation screen to test the connection to a specific IP address; follow these steps:
1. From the Main Menu, type
2. From the Utilities menu, type
3. At the prompt, type the IP address to PING and press <Tab>.
4. At the prompt, type the number of times to send a PING, from 1 to 256, or type
continuously every 3 seconds, and press <Enter>.
"
PING response received...
"
TIMEOUT: Unable to reach [IP address]...
5. To stop the PING and return to the Utilities menu, press <Esc>.
4-4
®
EdgeAccess
Universal Chassis System
, "Utilities," and press <Enter>.`
4
, "Reset Configuration To Default," press <Enter>, and then follow
6
, Diagnostics, and press <Enter>.
3
, PING Generation, and press <Enter>.
8
" indicates a good connection;
2346 T3 Modem
" indicates a faulty connection.
to PING
0