ABB ACS255 User Manual page 51

Drives 0.5...20 hp, 600v variants
Hide thumbs Also See for ACS255:
Table of Contents

Advertisement

52
Parameters in the Long parameter mode
Index
Name/Selection
32 SUPERVISION
3202
ADJUSTABLE THRESHOLD
1 LOWER LIMIT (ANALOG
OUTPUT 1 / RELAY
OUTPUT 1)
0.0 %...3203
3203
ADJUSTABLE THRESHOLD
1 UPPER LIMIT (ANALOG
OUTPUT 1 / RELAY
OUTPUT 1)
3202...200.0 %
3205
ADJUSTABLE THRESHOLD
1 LOWER LIMIT (ANALOG
OUTPUT 2 / RELAY
OUTPUT 2)
0.0...3206
3206
ADJUSTABLE THRESHOLD
1 UPPER LIMIT (ANALOG
OUTPUT 2 / RELAY
OUTPUT 2)
3205...200.0%
33 INFORMATION
3399
FIRMWARE UPGRADE
34 PANEL DISPLAY
3400
DISPLAY SCALING FACTOR
-30.000...30.000
3405
DISPLAY SCALING SOURCE
0 : Motor Speed
1 : Motor Current
2 : Analog Input 2
40 PROCESS PI SETUP
4001
PI PROPORTIONAL GAIN
0.0...30.0
4002
PI INTEGRAL TIME
CONSTANT
0.0...30.0 s
4005
PI Operating Mode
0 : DIRECT OPERATION
1 : INVERSE OPERATION
4010
PI Reference (Setpoint)
Source Select
0
1
2
4011
PI Digital Reference
(Setpoint)
0.0...100.0 %
4016
PI Feedback Signal Source
Select
0
1
Description
Signal supervision. The drive monitors whether certain user selectable variables are within
the user-defined limits. The user may set limits for speed, current etc. Supervision status can
be monitored with relay output. See parameter group 14 RELAY OUTPUTS.
Used in conjunction with some settings of parameter 1501 ANALOG OUTPUT 1 (TERMINAL 8)
FUNCTION SELECT & parameter 1401 USER RELAY 1 OUTPUT (TERMINALS 14, 15 & 16)
FUNCTION SELECT.
Used in conjunction with some settings of parameter 1501 ANALOG OUTPUT 1 (TERMINAL 8)
FUNCTION SELECT & parameter 1401 USER RELAY 1 OUTPUT (TERMINALS 14, 15 & 16)
FUNCTION SELECT.
Used in conjunction with some settings of Parameters 1507 ANALOG OUTPUT 2 (TERMINAL
11) FUNCTION SELECT & 1402 USER RELAY 2 OUTPUT (TERMINALS 17 & 18) FUNCTION
SELECT.
Used in conjunction with some settings of Parameter 1507 ANALOG OUTPUT 2 (TERMINAL
11) FUNCTION SELECT & 1402 USER RELAY 2 OUTPUT (TERMINALS 17 & 18) FUNCTION
SELECT.
Firmware update.
ABB Internal use only.
Selection of actual signals to be displayed on the drives front panel e.g. to display conveyer
speed in feet per second based on the output frequency
Allow the user to display an alternative output unit scaled from an existing parameter. This
function is disabled if set to 0.
If parameter 3400 DISPLAY SCALING FACTOR set >0, the variable selected in parameter 3405
DISPLAY SCALING SOURCE is multiplied by the factor entered in 3400 DISPLAY SCALING
FACTOR, and displayed whilst the drive is running, with a 'c' to indicate the customer scaled
units.
Hertz/Rpm
Ampere
%
Process PI control parameter set
PI Controller Proportional Gain. Higher values provide a greater change in the drive output
frequency in response to small changes in the feedback signal. Too high a value can cause
instability
PI Controller Integral Time. Larger values provide a more damped response for systems
where the overall process responds slowly
Use this mode if an increase in the motor speed should result in an increase in the feedback
signal
Use this mode if an increase in the motor speed should result in a decrease in the feedback
signal
Selects the source for the PI Reference / Setpoint
Digital Preset Setpoint. Parameter 4011 PI Digital Reference (Setpoint) is used
Analog Input 1 Setpoint
Analog Input 2 Setpoint
When parameter 4010 PI REFERENCE (SETPOINT) SOURCE SELECT = 0, this parameter sets
the preset digital reference (setpoint) used for the PI Controller
Analog Input 2
Analog Input 1
Def
0.0 %
100.0 %
0.0 %
100.0 %
0.000
0
1.0
1.0 s
0
0
0 %
0