Prevent detergent residue from
building up and odours from forming
by following these instructions:
Notes
Ensure the room in which the
washing machine is set up is well
ventilated.
Leave the door and detergent
dispenser tray open slightly when
the washing machine is not in use.
Occasionally run a wash using the
Cottons 60 °C programme and
powder detergent.
Machine housing/control
panel
Wipe the housing and the control
panel with a soft, damp cloth.
Remove the detergent residue
immediately.
Do not clean with a water jet.

Drum

Use chlorine-free cleaning agents, do
not use steel wool.
If there are odours in the washing
machine, or to clean the drum, run the
Drum Clean 90 °C programme without
laundry. Add washing powder.

Descaling

Descaling should not be necessary if
the detergent is measured out correctly.
However, if it is required, follow the
manufacturer's instructions for the
descaling agent. Suitable descalers can
be obtained via our website or from
customer services. ~ Page 43
Cleaning and maintenance
The drain pump is blocked,
emergency draining
:
Warning
Risk of scalding!
When you wash at high temperatures,
the water gets very hot. If you come into
contact with the hot water, you may be
scalded.
Allow the detergent solution to cool
down.
Turn off the water tap so that no
1.
more water can flow in and has to be
drained via the drain pump.
Switch off the appliance. Pull out the
2.
mains plug.
Open and remove the service flap.
3.
Take the auxilary drain hose out of
4.
the holder.
Remove the locking cap and drain
off the water into a suitable
container.
Replace the locking cap and place
the drain hose back in the holder.
Carefully unscrew the pump cover;
5.
remaining water may leak out.
Clean the interior, pump cover
thread and pump housing. The
impeller in the drain pump must be
able to rotate.
Refit and screw on the pump cover.
The handle must be in a vertical
position.