2. For storing press FUNC.
The display shows P3.
The unit is now in the mode "Master/Slave Open Interval".

P3 Setting the Master/Slave Open Interval

1. Press INC or DEC.
00 = Master gate and Slave gate open simultaneously.
01 = Master gate will open 1 second before the Slave gate.
02 = Master gate will open 2 seconds before the Slave gate.
03 = Master gate will open 3 seconds before the Slave gate, etc.
Factory setting is 3 sec. Max. 9 seconds are adjustable.
2. For storing press FUNC.
The display shows P4.
The unit is now in the mode "Master/Slave Close Interval".

P4 Setting the Master/Slave Close Interval

1. Press INC or DEC.
0 = Master gate and Slave gate will close simultaneously.
1 = Master gate will close 1 second after the Slave gate.
2 = Master gate will close 2 seconds after the Slave gate, etc.
Factory setting is 3 sec. Max. 9 seconds are adjustable.
2. For storing press FUNC.
The display shows P5.
The unit is now in the mode "Blocking Force for gate opener 1".
Programming