If only one gate opener in mounted, continue reading on page 23,
chapter "P5 Blocking Force for Gate Opener 1"!

P1 Programming dual Gate Openers

1. As soon as the control box is connected to power mains, the
display starts flashing and shows "– –". Now the unit is in
standby mode.
2. Hold the button FUNC pressed for more than 4 seconds.
The display shows P1.
The unit is in setting mode for operating 1 resp. 2 gate openers.
3. Press INC or DEC to start settings.
Setting 11 indicates operating mode for both gate openers
(factory setting).
4. For storing press FUNC.
The display shows P2.

P2 Setting Master/Slave Gate

The display shows P2. The unit is in "Master/Slave gate" setting
mode.
Master gate = this gate will open first and close last,
Slave gate = this gate will open with time delay and close first.
1. Press INC or DEC to start settings.
01 = gate opener 1 will open and close as Master gate.
10 = gate opener 2 will open and close as Master gate.
It is recommended to use gate opener 1 as
Mater gate! Please note that this depends
on how the gate is equipped (e. g. If a gate
folding (a) in installed on the gate).