Fig. 15
2.
Note and disconnect thermopile to high limit
switch wiring.
Fig. 16
3.
Loosen thermopile holding nut (1, Fig. 17).
F45691 (1117)
LG Series Fryer - REMOVAL AND REPLACEMENT OF PARTS
4.
Remove thermopile from bracket.
5.
Reverse to install.
All gas joints disturbed during servicing must be
checked for leaks. Check with a soap and water
solution (bubbles). Do not use an open flame.
1.
Remove HEAT SHIELD.
2.
Remove pilot assembly bracket.
Page 8 of 23
Fig. 17
PILOT
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.