Consumer Safety Information

Safety symbols and signal words

This is the safety alert symbol. This symbol
alerts you to potential hazards that can kill or
hurt you and others.
indicates a hazardous situation
which, if not avoided, will result in death or
serious injury.
indicates a hazardous situation
which, if not avoided, could result in death or
serious injury.
indicates a hazardous situation
which, if not avoided, could result in minor or
moderate injury.
is used to address practices not
related to physical injury.
Other important information or tips

Safety behavior and practices

Ensuring a safe operating environment
• Danger of suffocation! To ensure dis-
sipation of exhaust gases, operate the
Combi furnace outdoors only.
– Never use in enclosed spaces or tents or
breathe in the exhaust gases.
– If installing an airtight awning, make sure
that the exhaust system terminates to the
outdoors.
– If the RV is parked in an enclosed space:
– Block the flow of fuel to the Combi
furnace.
– Deactivate the time switch.
– Switch off the Combi furnace at the con-
trol panel.
– Ensure that the Combi furnace cannot be
switched on through the Truma App un-
der any circumstances.
• Use the Combi furnace only with a func-
tional LP gas and carbon monoxide detector
installed in the RV. For installation, operation
and function test follow the manufacturer's
guidelines.
6
• Keep the area around the Combi furnace free
from combustible materials, gasoline, and
other flammable vapors or liquids such as
pressurized dispensers or wax candles.
• Keep the area in front of the warm air outlets
(Fig. 1 – H) free of combustible or heat-sen-
sitive materials. Do not put any material into
the warm air outlets.
• In order to avoid overheating of the Combi
furnace, keep the air inlets of the Combi
furnace (Fig. 2 – 11), the air openings to the
area in which the Combi furnace is installed
(Fig. 1 – D) and the spacing around the
Combi furnace free of obstruction.
• To ensure clean combustion, keep the wall
cowl free of obstruction. Do not lean any ob-
jects against the wall cowl (Fig. 1 – F).
• Danger of hot surfaces. The temperature of
the exhaust gases can reach 320 °F (160 °C).
Do not touch the area around the wall cowl
and do not lean any objects against the wall
cowl or the RV.
Responsibilities of the operator
• The operator is responsible for the water filled
into the Combi water container and its quality.
• The operator is responsible for protecting the
Combi furnace against freezing.
Safe operation
• Use with LP gas (propane) only. Butane or
any mixtures containing more than 10 % of
butane must not be used.
– LPG tanks must be filled by a qualified gas
supplier only.
• Danger of damage to the gas system! For
the operation of gas pressure regulation sys-
tems, gas-burning devices or gas systems
only gas cylinders that supply gas in the
gaseous phase may be used. Gas cylinders
which supply gas in the liquid phase are
prohibited.
• Ensure that the interior of the RV is suf-
ficiently vented. The Combi furnace might
briefly emit smoke and an odor because of
dust or dirt when it is switched on, especially
if it has not been used in a long time.
– For using the Combi furnace in hot water
mode (140 °F (60 °C)), let it heat up several
times.