LK Systems 11-n Assembly Instructions Manual

Electric boiler

Advertisement

Quick Links

LK Electric Boiler 11-n
Construction
LK Electric Boiler -11, is a wall mountable and is
primarily designed for low-temperature heating
systems, e.g. under floor heating.
The boiler has the following features:
• Expansion vessel
• Safety valve
• Automatic air-bleeding valve
• Filling/drainage valve
• Overflow valve (safety valve device to pre-
vent overheating; if low flow rates it activa-
tes maximum safe temperature protection).
• Circulation pump, Grundfos UPM3 15-40
• Enclosure concealing pipe connections
LK Electric Boiler -11, is for space heating only,
not hot (washing) water.
Operation / Requirements
• Electronic temperature regulation with seven
settings from 1,6 kW to 11 kW.
The boiler is equipped with outside tem-
perature (weather) compensation, for auto-
matic control of internal temperature and
power output.
Other functions included in the electronic
controls:
• User selection of heating output at gradients
of 4-7.
• Overheating (maximum safe temperature)
safety function, this immediately shuts
down the boiler.
• Boiler temperature sensor and monitor.
• Status indication - indicating operational
status or malfunction.
• Input for external switching, e.g. room ther-
mostat.
• Input for remote control, incl. frost protec-
tion 10–20 °C.
• Circulation pump relay.
Sized for Kitchen Cabinets
LK Electric Boiler -11, can be wall hung or hidden
in a cupboard.
Its dimensions (WxHxD) are 546 x 601 x 180 mm,
so it can be mounted in most kitchen cabinets.
Assembly instructions | LK Electric Boiler 11-n
Technical data
Article no.
Height
Width
Depth
Weight
Volume capacity
Design pressure
Test pressure
Safety valve
Expansion vessel volume
Design temperature
Output
Voltage
Current
Fuses
Enclosure category
Condensing boiler
Low-temperature boiler
B1 boiler
Cogeneration space heater
Combination heater
Nominal output power
Usable output power
Energy class
Seasonal average efficiency
for space heating
Additional power consumption
Standby heat loss
623 12 24
601 mm
546 mm
180 mm
28 kg
2 liter
2,5 bar
3,3 bar
2,5 bar
12 liter
100 °C
6,3 - 11 kW
400V AC 3N~, 50 Hz
16,9 A
3 x 20 A
IP 21
No
No
No
No
No
P
11 kW
rated
P
11,0 kW
4
D
Boiler η
37%
s
Boiler with UTK 39%
In standby mode
P
0,003 kW
SB
P
0,022 kW
stby
EN.33.C.94.1702
1 (15)

Advertisement

Table of Contents
loading

Summary of Contents for LK Systems 11-n

  • Page 1 Assembly instructions | LK Electric Boiler 11-n LK Electric Boiler 11-n Construction LK Electric Boiler -11, is a wall mountable and is primarily designed for low-temperature heating systems, e.g. under floor heating. The boiler has the following features: • Expansion vessel •...
  • Page 2 Assembly instructions | LK Electric Boiler 11-n 13 14 18 20 13 14 Benämning 14. Return connector 1” female 1. Safety valve, 2.5 bar, ¾” female 15. Cable screwed unions ⅜ 2. Automatic air-bleeding valve, ” male 16. Knock-out opening, to be used when con- 3.
  • Page 3: Pipe Installation

    Assembly instructions | LK Electric Boiler 11-n Pipe installation Where the pressure or temperature is reduced, the vessel will be able to handle larger heating The electric boiler is mounted indoors, with the system volumes. pipe connections at the bottom.
  • Page 4 Assembly instructions | LK Electric Boiler 11-n Pump capacity PROP. PRESSURE: CURVE 1 [kPa] PROP. PRESSURE: CURVE 2 PROP. PRESSURE: CURVE 3 CONST. PRESSURE: CURVE 1 CONST. PRESSURE: CURVE 2 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]...
  • Page 5: Electrical Installation

    Assembly instructions | LK Electric Boiler 11-n Overflow valve The (under floor) heating system should not ex- ceed a flow pressure of 20 kPa. If all of the heating system valves close, circula- tion ceases in the boiler and there is a risk of over heating, then the “maximum safe temperature”...
  • Page 6 Assembly instructions | LK Electric Boiler 11-n Assisted by transformers, the loading relay mea- Switching off sures loading affecting the main fuses. Fuse size, 16 - 50 A, situated on the circuit board. The transformers are located on the wire from the fuses and must be protected.
  • Page 7 Assembly instructions | LK Electric Boiler 11-n The boiler’s output can be altered by using the 0 – 10V DC signal, which corresponds to 0%–100% of the boilers capacity as installed: see below. Con- nection is implemented to the base of the circuit board.
  • Page 8: Wiring Diagram

    Assembly instructions | LK Electric Boiler 11-n Wiring diagram WHITE 6 BROWN 11 WHITE 12 BROWN BLACK 5 WHITE 1 BROWN 10 WHITE 7 BLACK 4 BROWN 2 BLACK 8 BLACK 9 BROWN 3 10. Indicator for Output Group 2: 3.1 kW.
  • Page 9 Assembly instructions | LK Electric Boiler 11-n Settings Temperature setting in accordance with item 8, applies when inlet is open. When inlet is shut, or- dinary temperature setting applies. Main fuses’ rating size. Supply setting 20A. Temperature setting when regulated via remote control Circulation pump’s...
  • Page 10 Assembly instructions | LK Electric Boiler 11-n Control panel / Heating settings Front panel Temperature and manometer: Show boiler temperature / temperature of the outgoing water as well as heating system’s pressure. Main switch: Switches on and off all voltage to boiler.
  • Page 11 Assembly instructions | LK Electric Boiler 11-n Steady illumination Normal operation One long + one Delay in connection after a power outage limits output adjustment. short flash One long + two Loading relay, room thermostat or some other external control device limits output adjustment.
  • Page 12: Operation And Maintenance

    Assembly instructions | LK Electric Boiler 11-n Operation and maintenance and pressure. The expansion vessel accounts for some of the volume variation. Do not add water With installation completed, check with the instal- unless necessary. ler that the appliance is fully operational. Ask the...
  • Page 13 Assembly instructions | LK Electric Boiler 11-n Temperature setting freezing See item Control panel. Whenever there is a risk of freezing, do not shut down any part of the heating system as fracture may occur due to freezing. Should some part of...
  • Page 14: Troubleshooting

    Assembly instructions | LK Electric Boiler 11-n Troubleshooting Measures requiring tools should be carried out by a qualified installer. Begin troubleshooting by viewing the status indicators, see item 10, and Control panel. Fault Possible cause Remedial messure Operation and status Electric boiler without power.
  • Page 15 The insulation is removed and recycled as insu- lation. Boiler body and boiler casing recycled as scrap steel. Electrical and electronic components are sorted as electronic waste. EN.33.C.94.1702 LK Systems AB, Box 66, 161 26 Bromma, Sweden | www.lksystems.se 15 (15)

This manual is also suitable for:

623 12 24

Table of Contents