Technical Specifications - PowerDsine PD-6006 User Manual

Power over lan midspans 6/12/24-port models ieee 802.3af-compliant
Table of Contents

Advertisement

Symptom
Is it safe to keep
the Midspan
running while a port
indicator is orange?

Technical Specifications

Physical Specifications
Dimensions
(h x w x l)
Weight
Environmental Specifications
Temperature
- Operating
- Storage
Humidity
Electrical Specifications
Parameter
AC Input Voltage
DC Input Voltage
Input Current @ 115 VAC
Input at 48 VDC
Total Output Power (1)
Output Power, per Port
Nominal Output Voltage
Total Output Power (2)
(1) Using AC Power
(2) Using DC power
Power over LAN Solutions
Table 3-1: Troubleshooting Steps
This is a safe condition. The orange indication is due to:
1. A device, not compliant to IEEE 802.3af, was detected.
2. Terminals 4/5 and 7/8 are shorted together.
3. Forced external power fed into the port.
During these conditions, port power is disconnected.
44 x 433 x 302 mm
(1.75 x 17 x 11.9 inch)
4 kg (8.8 lb)
0 to 40 °C (32 to 104 °F)
-20 to 70 °C (-4 to 158 °F)
10 to 90% (non-condensing)
PD-6006
92 W max.
15.4 W (not to exceed Total Output Power)
14
Corrective Steps
PD-6012
90 to 264 VAC at 47-63 Hz
46 to 57 VDC
4 A max.
10 A max.
200 W max.
44 to 57 VDC
400 W
PD-6006/12/24
PD-6024
200 W max.
Cat. No.: 06-6800-056

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd-6012Pd-6024

Table of Contents