CONSUMER: READ AND SAVE THESE INSTRUCTIONS
DANGER
SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided
with this heater. Failure to comply can result in fire or explosion that can cause property
loss, bodily injury, or loss of life. Only persons who can follow and understand these
instructions should operate or service this heater. If you need heater info; such as an
operating manual, labels, etcetera, contact Pinnacle Climate Technologies at
800-779-3267.
DANGER
FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS
OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is an
unvented portable heater that uses air (Oxygen) from within the area in which it is used.
Failure to provide adequate combustion and ventilation air will result in asphyxiation, carbon
monoxide poisoning, bodily injury or death. Refer to "Ventilation" on Page 6.
WARNING
tions. Never use the heater in spaces which contain products such as; gasoline, solvents,
paint thinners, dust particles, volatile or airborne combustibles or any unknown chemicals.
This is an unvented portable heater. It uses air (Oxygen) from the area in which it is used.
Adequate combustion and ventilation air must be provided. Refer to "Ventilation" on page 6.
Bulk fuel storage should be a minimum of 25 feet from heater.
WARNING

OPERATING INSTRUCTIONS.

Failure to comply with the precautions and instructions provided with this
heater can result in death, serious bodily injury, property loss or damage
from the hazards of fire, soot production, explosions, burns, asphyxiation or
carbon monoxide poisoning. Only persons who can read and understand
these instructions should use or service this heater
U.S. Patent No. 9,644,863
®
Model Numbers
PT-70-SS-A / PT-125-OFR-A

Safety Information

GENERAL HAZARD WARNING:
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS
IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN
ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep
combustibles such as; building materials, paper or cardboard a safe
distance away from the heater as recommended by these instruc-
DO NOT OPERATE THIS HEATER UNTIL
YOU HAVE READ AND THOROUGHLY
UNDERSTAND THESE SAFETY AND
KEROSENE RADIANT HEATER
User's Manual &
Operating Instructions
.
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free
Fax: 320-251-2922 • Web:
www.protemp.us
© 2017 Pinnacle Climate Technologies, Inc.
Factory ID: 001
(800) 779-3267
• Email: info@pinnacleclimate.com
PTRA-401

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PT-125-OFR-A and is the answer not in the manual?

Questions and answers

Summary of Contents for Protemp PT-125-OFR-A

  • Page 1: Operating Instructions

    KEROSENE RADIANT HEATER User’s Manual & Operating Instructions ® Model Numbers PT-70-SS-A / PT-125-OFR-A CONSUMER: READ AND SAVE THESE INSTRUCTIONS Safety Information GENERAL HAZARD WARNING: DANGER READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER.
  • Page 2 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® DO NOT START THE HEATER WHEN EXCESS OIL HAS WARNING ACCUMULATED. WARNING DO NOT START THE HEATER WHEN THE CHAMBER IS HOT. CALIFORNIA RESIDENTS: This product contains chemicals, WARNING including lead, known to the State of California to cause birth defects or other reproductive harm.
  • Page 3: Specifications

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® NEVER block air outlet (front). WARNING RISK OF ELECTRIC NEVER use duct work in front of heater. SHOCK! NEVER move or handle heater while still hot. ALWAYS use only the electrical power (voltage and frequency) specified on the model plate of the heater.
  • Page 4 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Features 70-SS FUEL PRESSURE GAUGE (BEHIND REMOVABLE COVER) 125-OFR Top Safety Guard Radiant Cone Handle Front Safety Guard Radiant Fuel Cap Visors Wheel Frame Adjustment Knob º...
  • Page 5: Assembly Instructions

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Assembly Instructions 70-SS Tools Needed: Attach the handle while still in the box - Phillips Head Screw Driver for easier unpacking (see Figure 2). What’s In The Box Figure 1 Figure 2 Carry Handle (1)
  • Page 6 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Assembly Instructions 125-OFR What’s In The Box Long Screws (6) 8 mm Nuts (6) Visors (2) Short Screws (4) Wheels (2) Safety Guards Spacers (2) Wheel Frame 19 mm Axle Nuts (2) (Top, Front) Washers (2)
  • Page 7: Fueling The Heater

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Operation: 70-SS / 125-OFR Fueling The Heater: - NEVER use Kerosene that has been stored from one season to the next. Kerosene deteriorates Kerosene over time. OLD Kerosene WILL NOT BURN For optimal performance of this heater, it is PROPERLY IN THIS HEATER.
  • Page 8: Restarting The Heater

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Operation: 70-SS / 125-OFR Starting the Heater: (Ignition) Stopping the Heater: (Cool Down) 1. Fill the tank with Kerosene or other approved 1. Turn the power switch to the “OFF” position. fuel until needle on fuel gauge points to “F”.
  • Page 9: Fan Blades

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Maintenance: 70-SS / 125-OFR Long Term Storage: 1. Unscrew the fuel cap. 2. Using an approved siphon, remove the Kerosene or diesel. 3. Using a small amount of Kerosene or diesel, rinse and swirl the fuel inside the fuel tank NOTE: NEVER MIX WATER WITH FUEL.
  • Page 10 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Maintenance: 70-SS / 125-OFR Service (Continued): PHOTOCELL: The photocell should be cleaned at least once NOZZLES: per heating season or more depending on Nozzles should be cleaned or replaced at least conditions.
  • Page 11 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Troubleshooting Guide: 70-SS / 125-OFR Problem Possible Cause Solution 1. Dirty Fuel Filter. 1. Clean/replace Fuel Filter. 2. Nozzle Dirty. 2. Clean/replace Nozzle 3. Photocell Dirty. 3.
  • Page 12: Wiring Diagram

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Wiring Diagram 70-SS AC 250V 3.15A ELECTRIC OUTLET AC 120V/60Hz 125-OFR © 2017, Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 13: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Exploded View 70-SS © 2017, Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 14 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Parts List: 70-SS Item # Description 70-SS Fuel Filter 75-023-0285 Fuel Line 75-024-0510 Fuel Gauge 75-022-0200 Fuel Cap 70-006-0140 Cooling Fan Housing / Cooling Fan Housing Panel 75-011-0685 / 75-011-0690 Operating Switch 75-012-0110...
  • Page 15 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Exploded View 125-OFR © 2017, Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 16 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Parts List: 125-OFR Item # Description 125-OFR Fuel Filter 72-022-0100 Fuel Cap 72-006-0140 Wheel 72-041-1400 Axle 72-041-0200 Drain Bolt 72-002-0220 Height Adjustment Knob 72-042-0500 Return Fuel Line 72-023-0260 Intake Fuel Line 72-023-0260...
  • Page 17: Limited Warranty

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® LIMITED WARRANTY Pinnacle Climate Technnologies, Inc. warrants this If Pinnacle Climate Technnologies, Inc. finds the item heater to the original retail purchaser only, to be free from to be in normal operating condition, or not defective the defects in material and workmanship for a period of one (1) item will be returned freight collect.