Safety Information; General Instructions; Operation - WACKER Group IRFUN 38/115 Operator's Manual

Internal vibrator frequency converter
Table of Contents

Advertisement

Internal vibrators
2.

Safety information

for internal vibrators with integrated frequency converter
2.1

General instructions

2.1.1
2.1.2
2.1.3
2.1.4
2.2

Operation

2.2.1
2.2.2
SV00043en.fm
The IRFUN may only be worked on independently by persons who
are at least 18 years of age,
are physically and mentally fit for this job,
have been instructed in operating IRFUN and have proved their ability
for the job to the employer and
may be expected to carry out the job they are charged with carefully.
They must have been assigned to work on the IRFUN by the employer.
IRFUN is to be applied only for compacting work. Both the manufactur-
er's operator's manual and this safety information must be observed.
The machine must be immersed in the mass to be compressed.
The persons charged with the operation of IRFUN must be made fa-
miliar with the necessary safety measures relating to the machine. In
case of extraordinary uses, the employer shall give the necessary ad-
ditional instructions.
Observe the accident prevention regulations set forth by the profes-
sional association for electrical equipment and material and use them
as a basis during all work performed with this machine.
Make sure that IRFUN with electric motor drive is only attached to the
voltage and frequency indicated on the nameplate. The nameplate is
located on the inside of the switch box cover. The voltage to which the
machine must be connected is also embossed on the switch housing.
Choose correct cross section for extension cord.
IRFUN may only be connected to electric power supplies with a fault
current protective switch.
Either fault current protective switches of universal sensitivity must be
used or it must be ensured that the IRFUN is connected on its own
without any other consumers to an fault current protective switch de-
signed for non-sinusoidal current consumption.
When connecting the IRFUN to public mains networks, sockets with
15 A fuse must be used.