Whirlpool AGB 595/WP Instructions For Installation, Use And Maintenance Manual
Whirlpool AGB 595/WP Instructions For Installation, Use And Maintenance Manual

Whirlpool AGB 595/WP Instructions For Installation, Use And Maintenance Manual

Gas fryers

Advertisement

Quick Links

049_03
11/2005
Instructions for installation,
use and maintenance
GAS FRYERS
APPLIANCES WITH MECHANICAL VALVE
AGB 595/WP • AGB 596/WP
AGB 517/WP • AGB 518/WP
AGB 512/WP • AGB 513/WP

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool AGB 595/WP

  • Page 1 049_03 11/2005 Instructions for installation, use and maintenance GAS FRYERS APPLIANCES WITH MECHANICAL VALVE AGB 595/WP • AGB 596/WP AGB 517/WP • AGB 518/WP AGB 512/WP • AGB 513/WP...
  • Page 2: Table Of Contents

    INDEX Dimensions Running the appliance on other types page of gas page Data of appliances Replacing the main burner nozzle Adjusting the pilot burner Adjusting the primary air Technical data Maintenance Operating instructions Replacing parts Construction, equipment installed Valve and safety devices Safety termostat Assembly Burner...
  • Page 3: Dimensions

    Dimensions 1/2"GC 1/2"GC AGB 595/WP AGB 596/WP SKF 10GM 1/2"GC 1/2"GC AGB 513/WP AGB 512/WP 1/2"GC 1/2"GC 1/2"GC AGB 518/WP AGB 517/WP 049 - 03 - Gas fryers...
  • Page 4: Technical Data

    Dimensions Basins Nr. Capacity - Lt. (LxPxH+H ) - mm. AGB 595/WP Gas deep fat fryer - 1 tank - manual control 400 x 655 x 430-300 51BQ2904 AGB 596/WP Gas deep fat fryer - 2 tanks - manual control...
  • Page 5 TABLE 1 AGB 595/WP AGB 596/WP Model AGB 517/WP AGB 518/WP AGB 512/WP AGB 513/WP Category II2H3+ Construction type Air necessary for combustion Nominal thermal power 13.8 Minimum thermal power Overall thermal power (gas) AGB 595/WP AGB 517/WP AGB 512/WP AGB 596/WP 13.8...
  • Page 6: Operating Instructions

    OPERATING INSTRUCTIONS Construction, equipment installed Attention! and safety devices W h e n i n s t a l l i n g t h e A G B 5 9 5 / W P a n d Robust steel frame, with 4 legs (adjustable in hei- AGB 596/ WP models, make sure that the front ght).
  • Page 7: Installation Procedure

    Installation procedure Gas venting To level the appliance correctly, adjust the height of These appliances are A construction type, thus no the four legs. gas venting is required. For advice on ventilating the premises where the Gas connection appliance is installed, observe current regulations. The R 1/2”...
  • Page 8: Checking Power Rating When Using Lp Gas

    The heat value can be obtained from your local Gas - Draw up a servicing and maintenance contract. Board. To obtain the nominal capacity in relation to the no- Note for the installer minal pressure, consult table (1) (Gas Flow Setting). - Explain and demonstrate to the user how the machine works according to the instructions and WARNING...
  • Page 9: Adjusting The Pilot Burner

    Adjusting the pilot burner (Fig. 1) REPLACING PARTS To get at the pilot burner, remove the control panel (as previously described). Unscrew nut (34) and All parts must be replaced by authorised techni- using a screwdriver adjust the by-pass. For use with cians only! LPG, the adjusting screw must be fully screwed To replace the following parts, remove the control...
  • Page 10 AGB 517/WP AGB 518/WP AGB 595/WP AGB 596/WP AGB 512/WP AGB 513/WP 049 - 03 - Gas fryers...
  • Page 11: Using The Appliance

    USING THE APPLIANCE Warning! Lighting the main burner of the tank - Beware of inexpert handling! To ligth the main burner, turn the knob to the posi- - Old and dirty oil or frying fat can represent a real fi- tion required.
  • Page 12: Turning Off In An Emergency

    Floor-standing version TAKING CARE OF THE APPLIANCE FREQUENCY OF MAINTENANCE Check that the standard container is available for emptying procedure. The container should be pla- Warning! ced correctly on the proper guides and fully inser- ted. Never clean the appliance with jets of water, It is advisable to filter frying oil and fat daily and to whether direct or pressurised.