8.4.3.5
Preliminary Steps.
Once the DFG SETUP switch is turned
on, select the proper setting on the rotary switches at the rear of the drawer.
The "10 SEG/20 SEG/INV" switch should be in the "10 SEG" posi.'t"ion, which sep-
arates the unit into two independent 10-segment DFG's.
The switch marked
''MULT'' determines the maximum slope change per segment; rules for determining
the best setting are covered in Paragraph 8.4.4.
For the function such as
the one in Figure 8.2, a setting of "lll is adequate.
8
0
4.3.6
Slope Switches.
Turn all slope switches off for the
. . , DFG being set up.
8.4.3.7
Setting x and f(x).
Now set up the values of x and
f(x), starting from x
=
0 and proceeding out from the origin toward the
maxim1m x.
The breakpoint value is read directly on the DVM; to read the
corresponding function 'Talue, depress the appropriate switch.
Each switch
is momentary; it must be held down while setting f(x).
When the switch is
released, the breakpoint
~e
x is again displayed.
Table 8.2 gives detailed information on which switch to depress at any given
time.
The table applies to any ten"!'segment function with positive inputs;
the values of x and f(x) have been left blank, except for the initial and
final values of x, which must be zero and one.
Table 8 .. 2
Segment
Set X on
Then Hold Down
Set Y on This
Selector
X Value
This Point
this Button
Pot and Switch
Y Value
·While Setting Y
OFF
0
0
0000
None
PX
PARALLAX
2
BP2
SLOPE RO
SLl1(
3
BP3
SLOPE RO
. 'SL2
4
BP4
SLOPE RO
SL3
5
BPS
SLOPE RO
SL4
I
6
BP6
SLOPE RO
SL5
7
BP:]
SLOPE RO
SL6
8
BP8
SLOPE RO
SL7
9
BP9
SLOPE RO
SLB
10
BPIO
SLOPE RO
SL9
OFF
1.0000
None
+FINAL SLOPE
SLlO
*Use +CS position, not +SL position
o
-
-
8-11