4-6
the D/A switches operate at the REP-OP rate.
The D/A switches can be operated
independently of the REP-OP rate by removing the four
p~ong
bottle plug and
patching external logic signals to the OP and IC input (green) patch terminals.
4.2.3.2
Differentiator.
To operate the integrator as a differ-
entiator remove the bottle plug from the C patch terminal.
Connect two prong
bottle plug between a gain-of-one amplifier input and the amplifier output.
Select the desired capacitor value (see Paragraph 4.2.2, this chapter).
Patch
the signal to be differentiated to the C patch terminal.
The resultant differ-
entiated signal appears at the output of the amplifier.