Noritz NRCB199DV Owner's Manual

Noritz NRCB199DV Owner's Manual

Condensing gas combi boiler
Hide thumbs Also See for NRCB199DV:

Advertisement

CONDENSING GAS COMBI BOILER
Owner's Guide
WARNING
- Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
CERTIFIED
Low NOx Approved
by SCAQMD
14 ng/J or 20 ppm
(Natural Gas Only)
SBB80U9-1
Rev. 06/17
Models : NRCB199DV (GHQ-C3201WX-FF US)
NRCB180DV (GHQ-C2801WX-FF US)
FOR USE IN RESIDENTIAL OR MANUFACTURED HOME APPLICATIONS.
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury, or death.
Thank you for purchasing this Noritz Combi Boiler.
LOW-LEAD
Before using, please:
I
A P
M O
R
Read this manual completely for operation instructions.
& T
Completely fill out the warranty registration card (included separately) and
R
TM
mail the detachable portion to Noritz America Corporation.
Keep this manual (and the remainder of the warranty registration card)
where it can be found whenever necessary.
Installation must conform with local codes, or in the absence of local
codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition and
/or the Natural Gas and Propane Installation Code CSA B149.1 -latest edition.
Where required by the authority having jurisdiction, the installation must
conform to the Standard for Controls and Safety Devices for Automatically
Fired Boilers, ANSI/ASME CSD-1.
Noritz America reserves the right to discontinue, or change at any time,
the designs and/or specifications of its products without notice.
NORITZ America Corporation
*SBB80U9*

Advertisement

Table of Contents
loading

Summary of Contents for Noritz NRCB199DV

  • Page 1 Standard for Controls and Safety Devices for Automatically 14 ng/J or 20 ppm Fired Boilers, ANSI/ASME CSD-1. (Natural Gas Only) Noritz America reserves the right to discontinue, or change at any time, the designs and/or specifications of its products without notice. NORITZ America Corporation SBB80U9-1 Rev.
  • Page 2: Important Safety Information

    Important Safety Information-1 To prevent damage to property and injury to the user, the icons shown below will be used to warn of varying levels of danger. Every indication is critical to the safe operation of the Combi Boiler and must be understood and observed. Potential dangers from accidents during installation and use are divided into the following four categories.
  • Page 3 Be sure 1. Turn off the hot water supply. to do. some gas is heavier than air and 2. Turn off the heating system. will settle on the floor. 3. Turn off the power to the Combi Boiler. 4. Turn off gas, return/supply valve. WHAT TO DO IF YOU SMELL GAS. 5. Call the nearest Noritz agent • Do not try to light any appliance. Explosion Hazard ; • Do not touch any electrical switch; do not use any phone If the safety relief valve is dripping or in your building. leaking, have a qualified service technician Prohibited • Immediately call your gas replace it. Do not plug or remove the valve. supplier from a neighbor’s Failure to follow these instructions can result in phone. Follow the gas supplier’s...
  • Page 4 Min. 12" (300mm) gas on the rating plate. Be sure to do. Left side: Right side: e.g. For Natural Gas Min. 3" (75mm) Min. 3" (75mm) (NRCB199DV (GHQ-C3201WX-FF US)) Front: Sug. 24" (600mm) Indicates suggested clearances for maintenance. Carbon Monoxide Poisoning Hazard. Do not install this Combi Boiler in a recreational vehicle or on a boat. Prohibited Do not install this Combi Boiler Installation and service must be...
  • Page 5 (Continued) Consult the nearest Noritz agent if Do not place outdoors the Combi Boiler location needs to Rain may enter the unit or be changed. the burner fire may be blown Be sure Prohibited to do. by the wind, causing Outdoor malfunction or fire as a result. The gas conversion kit shall be installed by a qualified service agency in accordance with Contact a qualified service the manufacturer’s instructions and all applicable...
  • Page 6 Do not drink water that has been inside the Do not use parts other than those specified unit for an extended period of time. Do not for this equipment. drink the first use of hot water from the unit in the morning. This unit is only approved for installation up to 4500ft (1350m) above sea level. Clean the filter on the water inlet as For installations at higher elevations, contact Noritz frequently as required by the quality of America for Instructions. your local water. Do not disassemble the Operation Panel. Keep the area around the unit clean. Do not use benzene, oil or fat detergents If boxes, weeds, cobwebs, cockroaches etc. are in to clean the Operation Panel. the vicinity of the unit, damage or fire can result.
  • Page 7: Table Of Contents

    Contents Important Safety Information ............... 2 Contents......................7 General Parts Main Unit ....................8 Operation Panel..................10 Initial Operation ..................12 How to Use Clock Setting ..................... 13 Setting Domestic Hot Water Temperature (DHW) ........14 Setting Heating Temperature ..............16 Setting DHW Preheat Timer ..............17 Activate DHW Preheat ................19 Customizable Settings <User Mode> ............
  • Page 8: General Parts

    General Parts -1 Main Unit Intake Pipe Pressure Relief Valve (Heating) Exhaust Pipe Drain Pipe Front Cover Operation Panel Water Drain Valve Water Drain Valve (with Water Filter) Water Drain Valve (Inside Domestic Water Inlet) (with Water Filter) p.29) (Inside Heating Return Inlet) ( p.30) Water Supply Valve Water Drain Valve Water Drain Valve (with Water Filter) (Inside Auto Feeder Inlet) ( p.29) Gas Supply Valve Auto Feeder Shutoff Valve...
  • Page 9 The Condensing Gas Combi Boiler discharges condensate. When heat from the exhaust gas is collected within the secondary heat exchanger, condensation occurs from moisture in the exhaust gas and the resulting water is discharged from the drain pipe (approx. 2 gallons/hour (7.5 liters/hour) maximum). It is not a water leak. Do not plug or block the drain line as it must always be allowed to freely flow.
  • Page 10: Operation Panel

    General Parts -2 Operation Panel (RC-B201M) The Operation Panel will emit a tone when a button is pressed. Display Screen ( Next page) PREHEAT Button / TEMP Button Indicator(Orange) For setting and checking Activates the PREHEAT the Heating / Domestic “ON” or “OFF” setting as Hot Water (DHW) determined by the user temperature.( .14)
  • Page 11 Display Screen * The Display Screen shown below is for illustration purposes only. The actual display will vary depending on how the Combi Boiler is being used. Temperature Setting Clock Error Code Burner ON Icon During normal operation, A number will flash if a When burning, the icon the set temperature failure occurs.
  • Page 12: Initial Operation

    Initial Operation Before the first use of your Combi Boiler do the following: 1 through 5 Follow steps Open the water supply valve and the auto feeder shutoff valve. OPEN CLOSED Open a hot water fixture to confirm that water is available, and then close the fixture again.
  • Page 13: Clock Setting

    Clock Setting 2,3,4 Operation Screen Display Description * This setting can be done regardless of Press the button. whether the button is ON/OFF. Press the button. After 1 sec. (CLS:CLock Setting) Press the button. * Each press of the button changes the time in 1-minute increments.
  • Page 14: Setting Domestic Hot Water Temperature (Dhw)

    Setting Domestic Hot Water Temperature (DHW) Operation Screen Display Description * The indicator is lit. Press the button ON. (e.g.: 10:15AM) * To return to the home screen, press the Press the button twice. button or let panel sit for The current "DHW approximately 20 seconds.
  • Page 15 * For most residential applications, the recommended temperature setting is 120°F (50°C in °C mode) or less. * Consult local codes for minimum operating temperatures. Note : Noritz recommends that water temperature is set as low as possible to prevent scale build-up in the heat exchanger.
  • Page 16: Setting Heating Temperature

    • The unit has the "Outdoor Reset (Energy Saving)" feature, but this feature is disabled (Factory Default). • To enable, contact your installer or Noritz America Technical Support at 866-766-7489. ) is lit on the Operation Panel, the Outdoor Reset (Energy Saving) is enabled.
  • Page 17: Setting Dhw Preheat Timer

    Setting DHW Preheat Timer This example shown is setting the "ON time" and "OFF time" to 6:00PM and 7:00PM. Press the button ON. (e.g.: 10:15AM) * In order to use the DHW Preheat function, Press and hold the clock must be set first. The DHW Preheat button for Timer is disabled until the clock is set. * When entering DHW Preheat Timer setting (e.g.: 12:00PM) approximately 2 seconds.
  • Page 18 e.g. DHW Preheat is scheduled to run 7:00AM - 8:00AM, 11:30AM - 1:00PM and 6:00PM - 9:00PM. Screen Display Screen Display Screen Display...
  • Page 19: Activate Dhw Preheat

    Activate DHW Preheat Operation Description * When Operation Panel is OFF, you can not activate Press the button ON. DHW Preheat. * When Preheat is activated, indicator is lit. Press the button. * To deactivate DHW Preheat, Press the button. To Confirm DHW Preheat Operation When Preheat is operating, DHW Preheat Icon is lit. DHW Preheat Icon...
  • Page 20: Customizable Settings

    Customizable Settings <User Mode> Adjusting the DHW Maximum Muting the Operation Panel. Output Temperature. The Operation Panel can be muted The DHW maximum output so that no tone is emitted when a temperature can be limited to prevent button is pressed. discharging hot water at too high of a temperature.
  • Page 21 Draining the Combi Boiler. Temperature Lock. Refer to page 26 for details.) Temperature Settings can be locked so that it does not change temperature setting if a button is pressed by mistake. Both DHW and Heating temperature setting are locked. Press the button OFF.
  • Page 22: Guide For Functions

    (not flashing), then the Combi Boiler operates simultaneously DHW and Heating automatically by increasing the heating supply temperature. * Contact Noritz America for more information about simultaneous use for DHW and Heating. Outdoor Reset ) is lit on the Operation Panel, the Outdoor Reset (Energy Saving) is enabled.
  • Page 23: View Technical Data

    View Technical Data Operation Screen Display Description * This setting can be done regardless of Press the button. whether the button is ON/OFF. (td:technical data) Press the button. (Data No. 03) After 2 sec. (e.g.: 100) * Press and hold the button to change it in Press the buttons to increments of 10.
  • Page 24: Preventing Damage From Freezing

    * The freeze prevention of the Combi Boiler will not prevent the plumbing external to the unit from freezing. Protect this plumbing with insulation, heat tape or electric heaters, solenoids, or pipe covers. If there remains a freezing risk, contact the nearest Noritz agent. Take the measures below for extremely cold temperatures*.
  • Page 25 If water will not flow because it is frozen 1. Close the gas and water valves. 2. Turn off the power button. 3. Open the water supply valve from time to time to check whether water is running. 4. When the water is flowing again, check for water leaks from the equipment and piping before using. If the Combi Boiler or the piping is frozen, do not use the Combi Boiler or it may get damaged.
  • Page 26 Preventing Damage from Freezing-2 If the Combi Boiler will not be used for a long period of time, drain the water. Drain the water as follows: CAUTION To avoid burns, wait until the equipment cools down before draining the water. The appliance will remain hot after it is turned off.
  • Page 27 Turning the Unit Back On 1. Check that all drain plugs are inserted. 2. Check that all hot water fixtures/faucets are closed. 3. Follow the procedure on p.12 “Initial operation”, steps 1 through 5. 4. Make sure that the area around the appliance is well ventilated; open a window or a door if necessary. Then, operate the unit and verify that condensate is coming out of the drain pipe.
  • Page 28: Regular Maintenance

    Regular Maintenance-1 Periodic Inspection CAUTION To prevent burns or scalding, turn off the power button and wait until the equipment cools before performing maintenance. Be sure to do. [When supplying combustion air For dust and soot in Check from the indoors] the exhaust vent or Air Intake For smear or blockage...
  • Page 29 Periodic Maintenance Unit Wipe the outside surface with a wet cloth, then dry the surface. Use a neutral detergent to clean any stains. If an external condensate neutralizer is installed, periodic replacement of the neutralizing agent will be required. Refer to the instructions supplied with the neutralizer for suggested replacement intervals. Operation Panel Wipe the surface with a wet cloth.
  • Page 30 • Before using anti freeze products, ensure that system fluid contains proper glycol concentration and the inhibitor level is appropriate. Noritz recommends against exceeding a 50% concentration of glycol. • When using the anti freeze products, the system must be tested at least once a year, and as...
  • Page 31 (http://support.noritz.com/ or 866-766-7489) Damage to the Combi Boiler as a result of below is not covered by the Noritz America Limited Warranty. To ensure full warranty coverage, treat or condition water that exceeds the target levels provided in this table.
  • Page 32: Troubleshooting

    Troubleshooting-1 Initial Operation • Check for reversed plumbing or crossed pipes. Unit does not attempt to ignite when water is running. • Check the water drain valve filter. ( p.29, p.30) Unit attempts to ignite but fails • Reset unit and try again. There may be air in the gas line. •...
  • Page 33 • When hot water is demanded at other fixtures, the amount available may be reduced. The maximum flow available from fixture is not constant. NRCB199DV (GHQ-C3201WX-FF US) and NRCB180DV(GHQ-C2801WX-FF US) are 8.4 GPM (32L/min.) and 7.5GPM (28.2L/min.), respectively at a 45°F (25°C) temperature rise.
  • Page 34 Troubleshooting-2 Operation Panel The power ON/OFF indicator • Has there been a power failure? does not light up. • Is the power connected properly? The clock display shows • If the time has not been set, The clock display shows "- : - -".
  • Page 35 Other The Combi Boiler stops burning • Are the gas and water supply valves fully open? during operation. • Is the water supply cut off? • Is the hot water fixture/faucet sufficiently open? • Is the gas being cut off by the gas meter? (Can other gas devices such as stoves be used?) •...
  • Page 36 Service Reminder This unit is equipped with an automatic service reminder. (Warning Indication) If the display shows “88”, contact the nearest Noritz agent. [When supplying combustion Check air supply vent for blockage or obstruction. p.28)
  • Page 37: Follow-Up Service

    For repairs after the warranty period, there will be a charge on any service, and service will only be performed if the unit is deemed repairable. Period of Time for Stocking Repair Parts Noritz will stock repair and maintenance parts for this unit within ten (10) years of the date of the original installation. Reinstallation If you want to reinstall the appliance at a different location, confirm that the gas and power supply indicated on the rating plate are available at the new location.
  • Page 38: Gas Conversion

    This work must be performed by either Noritz or a qualified service agency and will be charged for even during the warranty period. The qualified installer will also be responsible for purchasing the gas conversion kit directly from the manufacturer.
  • Page 39: Specifications

    • Specifications may be changed without prior notice. • The capacity may differ slightly, depending on the water pressure, water supply, piping conditions, and water temperature. Specifications Item Specification Model Name NRCB199DV(GHQ-C3201WX-FF US) NRCB180DV(GHQ-C2801WX-FF US) Indoor Wall Mounted Installation Type Power Vented Air Supply/Exhaust...
  • Page 40 *2 The Net AHRI water ratings shown are based on a piping and pickup allowance of 1.15. Consult Noritz before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping system, etc.

This manual is also suitable for:

Ghq-c3201wx-ff usNrcb180dvGhq-c2801wx-ff us

Table of Contents