Download Print this page

Honeywell DT7500SN V-Plex DUAL TEC Installation Instructions page 3

Motion sensor

Advertisement

DT7500SN V-Plex
! ! ! !
b
FOR PET IMMUNITY
<SPANISH>
Mount the center of the sensor at 2.3 m (7.5 feet) high.
Set the sensor to the Lowest or Low sensitivity (see step 6a).
Install Pet Immune lens (5-532-489-01 - see Lens Change
Instructions on page 3).
Install the look-down mask (see Step 6a).
Install the sensor where pets cannot come within 1.8 m (6 ft) of the
sensor by climbing on furniture or other objects.
Aim the sensor away from stairways, furniture or other objects that
can be climbed on by pets.
TEST the installation site to determine the exact level of attainable
animal immunity.
Note: Pet immunity characteristics for this sensor have not been verified by
Underwriter's Laboratories, Inc.
" " " "
PROGRAM SENSOR SERIAL NUMBER ID
Each sensor has a factory-assigned serial number which must be
entered into the control panel during the zone programming procedure.
The unique serial number can be found on a bar code label on the
sensor PCB. The serial number can be entered into the control panel in
one of the following methods:
A. Download it through software (Zone definition screen of Compass
software). This is recommended for large installations and
installations where foot traffic cannot be controlled.
B. Enter the number through the keypad at the "INPUT S/N" prompt
during manual zone programming. Ensure no other polling devices
are activated when manually entering the sensor serial number.
C. Activate the sensor twice while at the "INPUT S/N" prompt during
manual zone programming.
To enter the sensor's serial number for option B or C:
Refer to the control panel's manual for programming instructions.
TM
For all V-Plex
panels, enter INT FOLLOWER 04 for the Zone Type and
"06" for SL (Serial Polling Device) at the "INPUT TYPE" prompt. For
TM
Smart V-Plex
panels press "1" (Yes) for SMART CONTACT.
At the "INPUT S/N" prompt, either enter the serial number (and "1" for
the loop number), or fault the sensor (wave your hand in front of the
sensor or activate the tamper), then wait 3-6 seconds and fault the
sensor again. The keypad will beep after each fault to confirm the signal.
The sensor should now be enrolled. If a "1" does not appear under the
"L" on the zone summary screen, press [*] and enter the loop number
manually at the next screen.
# # # #
NORMAL WALK TEST – 10 MINUTES
Normal walk test mode activates after power up mode and remains
active for 10 minutes. For an additional 10 minutes of walk test time,
remove and replace the front cover. In walk test mode, the LED is
always enabled, regardless of the LED DIP switch setting. [Note: if the
TM
panel is not a Smart V-Plex
panel, walk test can also be done by
enabling the LED (DIP switch 3 = ON.]
Walk through the detection area and observe the LED.
If necessary, adjust the microwave range, pulse count or sensitivity
setting. (For LED activation meaning, refer to the LED Indicator table
below.)
$ $ $ $
MICROWAVE WALK TEST – 10 MINUTES
1. Set the Microwave Walk Test DIP switch to ON, or toggle it ON and
OFF.
2. Set Range Adjustment potentiometer to 25% and replace the cover.
3. Walk through the detection area and observe the LED.
4. If necessary, adjust the potentiometer until desired detection range is
obtained. (For LED activation meaning, refer to the LED Indicator
table below.)
Indicator LEDs
Condition
Indicator LED
Power Up
Slow Blinking Red (will finish within
60 seconds)
Normal Walk Test
Red ON for 3 seconds if Alarm
Yellow ON for 2 seconds if Microwave
event detected
Green ON for 2 seconds if PIR event
detected
Microwave Walk Test
Red ON if Microwave is set too high
Green ON if Microwave is set correctly
OFF if Microwave is set too low
Trouble or Anti-Mask
Fast Blinking Red (LED Enabled
or Disabled)
% % % %
ANTI-MASK
When DIP switch 5 is set to ON, the sensor indicates a mask condition
(see LED Indicator table above) when a variety of materials and
reflective objects are placed in front of it. Follow the mounting guidelines
in step 1 to avoid false mask alarms.
To clear a mask condition, visually inspect the sensor and remove any
materials blocking the sensor's view. The sensor will clear an anti-mask
condition when three valid alarms are detected. After a mask condition
is cleared, fully walk test the required detection area.
TROUBLESHOOTING
RED LED flashing rapidly during normal operation indicates a trouble or
an anti-mask condition. If the sensor is not masked (see step 10), either
a microwave, PIR, or temperature compensation fault is present.
Solution: Momentarily power down the sensor. If the trouble does not
clear, replace the sensor. (Please check the power, all wiring and that
the sensor is not masked before replacing the sensor.)
DETECTION PATTERNS / COUVERTURE DE DETECTION / DIAGRAMMA DI COPERTURA /
PATRON DE DETECCIÓN /
DETECTION PATTERNS
35' / 11m Pet Immune Lens (P/N 5-532-489-01 – Included)
Top View / VUE DE DESSUS / Vista in pianta / VISTA DESDE ARRIBA /
   
TM
DUAL TEC
Motion Sensor - Installation Instructions
! ! ! !
b
FOR PET IMMUNITY
Mount the center of the sensor at 2.3 m (7.5 feet) high.
Set the sensor to the Lowest or Low sensitivity (see step 6a).
Install Pet Immune lens (5-532-489-01 - see Lens Change
Instructions on page 3).
Install the look-down mask (see Step 6a).
Install the sensor where pets cannot come within 1.8 m (6 ft) of the
sensor by climbing on furniture or other objects.
Aim the sensor away from stairways, furniture or other objects that
can be climbed on by pets.
TEST the installation site to determine the exact level of attainable
animal immunity.
Note: Pet immunity characteristics for this sensor have not been verified by
Underwriter's Laboratories, Inc.
" " " "
PROGRAM SENSOR SERIAL NUMBER ID
Each sensor has a factory-assigned serial number which must be
entered into the control panel during the zone programming procedure.
The unique serial number can be found on a bar code label on the
sensor PCB. The serial number can be entered into the control panel in
one of the following methods:
A. Download it through software (Zone definition screen of Compass
software). This is recommended for large installations and
installations where foot traffic cannot be controlled.
B. Enter the number through the keypad at the "INPUT S/N" prompt
during manual zone programming. Ensure no other polling devices
are activated when manually entering the sensor serial number.
C. Activate the sensor twice while at the "INPUT S/N" prompt during
manual zone programming.
To enter the sensor's serial number for option B or C:
Refer to the control panel's manual for programming instructions.
TM
For all V-Plex
panels, enter INT FOLLOWER 04 for the Zone Type and
"06" for SL (Serial Polling Device) at the "INPUT TYPE" prompt. For
TM
Smart V-Plex
panels press "1" (Yes) for SMART CONTACT.
At the "INPUT S/N" prompt, either enter the serial number (and "1" for
the loop number), or fault the sensor (wave your hand in front of the
sensor or activate the tamper), then wait 3-6 seconds and fault the
sensor again. The keypad will beep after each fault to confirm the signal.
The sensor should now be enrolled. If a "1" does not appear under the
"L" on the zone summary screen, press [*] and enter the loop number
manually at the next screen.
# # # #
NORMAL WALK TEST – 10 MINUTES
Normal walk test mode activates after power up mode and remains
active for 10 minutes. For an additional 10 minutes of walk test time,
remove and replace the front cover. In walk test mode, the LED is
always enabled, regardless of the LED DIP switch setting. [Note: if the
TM
panel is not a Smart V-Plex
panel, walk test can also be done by
enabling the LED (DIP switch 3 = ON.]
Walk through the detection area and observe the LED.
If necessary, adjust the microwave range, pulse count or sensitivity
setting. (For LED activation meaning, refer to the LED Indicator table
below.)
$ $ $ $
MICROWAVE WALK TEST – 10 MINUTES
1. Set the Microwave Walk Test DIP switch to ON, or toggle it ON and
OFF.
2. Set Range Adjustment potentiometer to 25% and replace the cover.
3. Walk through the detection area and observe the LED.
4. If necessary, adjust the potentiometer until desired detection range is
obtained. (For LED activation meaning, refer to the LED Indicator
table below.)
Indicator LEDs
Condition
Indicator LED
Power Up
Slow Blinking Red (will finish within
60 seconds)
Normal Walk Test
Red ON for 3 seconds if Alarm
Yellow ON for 2 seconds if Microwave
event detected
Green ON for 2 seconds if PIR event
detected
Microwave Walk Test
Red ON if Microwave is set too high
Green ON if Microwave is set correctly
OFF if Microwave is set too low
Trouble or Anti-Mask
Fast Blinking Red (LED Enabled
or Disabled)
% % % %
ANTI-MASK
When DIP switch 5 is set to ON, the sensor indicates a mask condition
(see LED Indicator table above) when a variety of materials and
reflective objects are placed in front of it. Follow the mounting guidelines
in step 1 to avoid false mask alarms.
To clear a mask condition, visually inspect the sensor and remove any
materials blocking the sensor's view. The sensor will clear an anti-mask
condition when three valid alarms are detected. After a mask condition
is cleared, fully walk test the required detection area.
TROUBLESHOOTING
RED LED flashing rapidly during normal operation indicates a trouble or
an anti-mask condition. If the sensor is not masked (see step 10), either
a microwave, PIR, or temperature compensation fault is present.
Solution: Momentarily power down the sensor. If the trouble does not
clear, replace the sensor. (Please check the power, all wiring and that
the sensor is not masked before replacing the sensor.)
Top View
Side View / VUE DE COTE / Vista in sezione /
VISTA LATERAL /
Side View
Install Look Down Mask to block look down zones.
Install Look Down Mask to block look down zones.
Install Look Down Mask to block look down zones.
Install Look Down Mask to block look down zones.
Install Look Down Mask to block look down zones.
- Page 3 -
<PORTUGUESE>
ACCESSORIES / ACCESSOIRES / ACCESSORI / ACCESORIOS /
ACCESSORIES
SMB-10
(P/N 0-000-110-01)
SMB-10C
(P/N 0-000-111-01)
SMB-10T
(P/N 0-000-155-01)
EN 50131-1 &
EN50131-2-4
NCompliant
DT7000-LRLK
15 m x 3 m
(50' x 10')
DT7000-HSLK
11 m x 12 m
(35' x 40')
DT7000-PALK
11 m x 12 m
(35' x 40')
LENS CHANGE INSTRUCTIONS /
LENS CHANGE INSTRUCTIONS / LENS CHANGE INSTRUCTIONS /
LENS CHANGE INSTRUCTIONS
LENS MASKING /
MASKING / LENS MASKING
Swivel Mount Bracket
Rotule de montage
Snodo da parete
Rotula de montaje a pared
Swivel Mount Bracket
Swivel Mount Ceiling Bracket
Rotule de plafond
Snodo da soffitto
Rotula de montaje a techno
Swivel Mount Ceiling Bracket
Swivel Mount Bracket w/Tamper
Rotule de montage avec autoprotection
Snodo da parete con tamper
Rotula de montaje a pared con tamper
Swivel Mount Bracket w/Tamper
Long Range Lens Kit
Kit lentille longue portée
Kit lenti a lunga portata
Kit de lentes de largo alcance
Long Range Lens Kit
High Security Lens Kit
High Security Lens Kit
High Security Lens Kit
High Security Lens Kit
High Security Lens Kit
Pet Alley Lens Kit
Pet Alley Lens Kit
Pet Alley Lens Kit
Pet Alley Lens Kit
Pet Alley Lens Kit
LENS CHANGE INSTRUCTIONS /
LENS MASKING / LENS MASKING / LENS
TOP

Advertisement

loading