Cisco ASR 902 Installation Manual page 8

Table of Contents

Advertisement

Installing the Chassis Ground Connection
1
To ensure that the chassis ground connection that you provide is adequate, you need the following parts and
tools:
• Ratcheting torque screwdriver with Phillips head that exerts up to 15 in.-lb (1.69 N-m) of pressure for
attaching the ground wire to the router
• Crimping tool as specified by the ground lug manufacturer
• 6-AWG or larger copper wire for the ground wire
• Wire-stripping tools appropriate to the wire you are using
Before making connections to the Cisco ASR 902 Router, ensure that you disconnect the power at the
Caution
circuit breaker. Otherwise, severe injury to you or damage to the router may occur.
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
Warning
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority
or an electrician if you are uncertain that suitable grounding is available. Statement 1024
Warning
Use copper conductors only. Statement 1025
When installing or replacing the unit, the ground connection must always be made first and disconnected
Warning
last. Statement 1046
This unit is to be installed in a restrictive access location and must be permanently grounded to a minimum
6-AWG copper ground wire.
Cisco ASR 902 and ASR 902U Aggregation Services Router Hardware Installation Guide
8
Installing the Cisco ASR 902 Router
Grounding lug (300 mm ETSI cabinet)

Advertisement

Table of Contents
loading

Table of Contents