Huawei MG301 Hardware Manual page 38

B2b module
Table of Contents

Advertisement

HUAWEI MG301 B2B Module
HardwareGuide
Table 5-6 Working current of the MG301 B2B module
Working Mode
Power-off mode
Sleep mode
Idle mode
Current in the sleep mode indicates that module enters in the sleep mode (AT+CFUN=0),
and the serial port cannot be used.
The typical values are the average of some test samples.
In idle mode, the module is registered to the network; no voice or data service is ongoing
and the serial port can be used.
Table 5-7 Working current of the MG301 B2B module (for GPRS mode)
Band
Typical
value
GPRS850
242
438
136
220
GPRS900
252
455
138
225
GPRS1800
185
340
85
127
GPRS1900
181
336
Typical value
Unit
50.00
µA
1.50
mA
0.89
mA
0.85
mA
50.00
mA
Unit
PCL
Configuration
mA
5
1 Up/1 Down
2 Up/1 Down
mA
10
1 Up/1 Down
2 Up/1 Down
mA
5
1 Up/1 Down
2 Up/1 Down
mA
10
1 Up/1 Down
2 Up/1 Down
mA
0
1 Up/1 Down
2 Up/1 Down
mA
10
1 Up/1 Down
2 Up/1 Down
mA
0
1 Up/1 Down
2 Up/1 Down
Huawei Proprietary and Confidential Copyright ©
Huawei Technologies Co., Ltd
Issue 06 (2013-06-13)
Electrical and Reliability Features
Remark
VBAT is powered on, yet the
module is in power-off state.
MFRMS=2
MFRMS=5
MFRMS=9
MFRMS=5
41