Calling up
Calling up information and resetting values
Display
0 0 0 5 0 6
7
0 0 0 5 0 6
8
0 0 2 8 5 0
9
4
1
2

Calling up a service message

Your heating contractor can set a service interval. For
example, burner service after 2500 hours run or serv-
ice after 12 months.
If your heating system is due for a service, the symbol
" " flashes on the display and the expired service
interval is shown.
Example:
Service display with the service interval of 2500 hours
run by the burner:
ë
2 5 0
0
Fig. 5
Service display with the service interval of 12 months:
ë
1
Fig. 6

Calling up fault messages

If any faults have occurred in your heating system, the
symbol " " flashes on the display and the fault code
is shown. In addition, the red fault indicator flashes
(see page 9).
16
Meaning
h
Hours run, output 22
Pump starts, output 22
Solar yield in kWh
Reception quality Vitocom 100,
type GSM
h
2
(cont.)
Notes
Displayed only if the Viessmann solar control
module is available and a second circulation
pump has been connected.
The hours run can be reset to "0" with "
Displayed only if the Viessmann solar control
module is available and a second circulation
pump has been connected.
The pump starts can be reset to "0" with "
Displayed only if a Viessmann solar control
module is installed.
The solar energy can be reset to "0" with "
Displayed only if Vitocom 100, type GSM is con-
nected.
0 - no reception
5 - very good reception
Notify your local heating contractor and acknowledge
the service message by pressing OK.
Note
If the service can only be carried out at a later point in
time, the service message will reappear after 7 days.
Calling up an acknowledged service message
Press OK for approx. 4 seconds.
".