LG MULTI F Engineering Manual page 29

Multi f; multi f max with lg red heat pump outdoor unit
Hide thumbs Also See for MULTI F:
Table of Contents

Advertisement

F
MULTI
MAX
WITH
Table 17:
Capacity
Nominal
Cooling (Btu/h) (Min.~Rated~ Max.)
Cooling Power Input (kW) (Min.~Rated~ Max.)
Cooling Running Current (A) (Min.~Rated~ Max.)
Heating (Btu/h) (Min.~Rated~ Max.)
Heating Power Input (kW) (Min.~Rated~ Max.)
Heating Running Current (A) (Min.~Rated~ Max.)
Operating Range
Cooling (°F DB)
2
Heating (°F WB)
Compressor
Inverter Quantity
Oil / Type
Fan (Side Discharge)
Type
Motor Output (W) x Qty.
Motor / Drive
Maximum Air Flow Rate (ft.
/ min.)
3
Unit Data
Refrigerant Type
Refrigerant Control / Location
Min. Number Indoor Units / System
Max. Number Indoor Units / System
Max. Number of Branch Distribution Units
Maximum Allowable Total Indoor Unit Connected Capacity (Btu/h)
Sound Pressure ±3 dB(A) (Cooling / Heating) dB(A)
Dimensions (W x H x D [inch])
Net Unit Weight (lbs.)
Power Supply (V, Phase, Hz)
Communication / Connection (Power) Cable from ODU & BDU / BDU & IDU (No. X AWG)
Heat Exchanger
Material and Fin Coating
Rows/Columns / Fins per inch x Qty.
Piping
Liquid Line Connection (in., O.D.) x Qty.
Vapor Line Connection (in., O.D.) x Qty.
Factory Charge oz. of R410A
Additional Charging Volume (oz. / ft.)
Piping Lengths
Maximum Total Piping (ft.)
7
Maximum Piping Length (No Additional Refrigerant [ft.])
Maximum Main Pipe Length (Outdoor Unit to Branch Distribution Unit [ft.])
Total Branch Piping (Branch Distribution Unit to all Indoor Units [ft.])
Maximum Branch Pipe Length (Length between each BDU & IDU [ft.])
Maximum Outdoor Unit to Indoor Unit Pipe Length (ft.)
Maximum Elevation between Outdoor Unit and Indoor Unit (ft.)
Maximum Elevation between Indoor Unit and Indoor Unit (ft.)
Maximum Elevation between Branch Distribution Unit and Indoor Unit (ft.)
Maximum Elevation between Branch Distribution Unit and Branch Distribution Unit (ft.)
Rated capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with a 0 ft. level differ-
1
ence between outdoor and indoor units. All capacities are net with a combination ratio between 95 – 105%.
Rated cooling capacity obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Rated heating capacity obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
2
Cooling range with Low Ambient Wind Baffle Kit (sold separately) is -4°F to +118°F.
At least one Branch Distribution Unit is required for system operation; a maximum of two can be
3
installed per outdoor unit with use of Y-branch accessory (PMBL5620). At least two indoor units should
be connected. For allocated capacity information, see the combination tables in the "Multi F / Multi F
MAX with LGRED Combination Data Manual" on www.lg-dfs.com. For performance data, see "Multi F /
Multi F MAX with LGRED Performance Data Manual" on www.lg-dfs.com.
Model Number
1
1
3
3
4
Main Pipe
Branch Pipe
©
MULTI F MAX WITH LGRED
LMU360HHV
36,000
11,700~36,000~46,733
0.72 ~ 2.40 ~ 3.75
3.9 ~ 13.0 ~ 20.4
13,455~41,000~50,200
0.96 ~ 2.93 ~ 3.94
5.2 ~ 15.9 ~ 21.4
Brushless Digitally Controlled / Direct
Electronic Expansion Valve / Outdoor Unit
5
48,000
5,6
Copper Tube/Aluminum Fin and GoldFin™ / Hydrophilic
(2 x 32 x 14) x 2, (1 x 32 x 14) x 2
16.4 ft. of Main Piping +131.2 ft. of Branch Piping
Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745. These values can
4
increase due to ambient conditions during operation.
5
Power wiring to the outdoor unit is field supplied, solid or stranded, and must comply with the applica-
ble local and national codes. For detailed information, please refer to electrical characteristics on page
30.
6
All communications / connection (power) cable to be minimum 16 AWG from the outdoor unit to the
BD unit, and 18 AWG from the BD unit to the indoor unit, stranded, shielded or unshielded (if shielded,
it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and
national codes. For detailed electrical information, please refer to electric characteristics on page 30.
Piping lengths are equivalent.
7
General Data
LMU420HHV
42,000
11,700~42,000~53,897
0.72 ~ 3.00 ~ 4.34
3.9 ~ 16.3 ~ 23.6
13,455~45,000~55,256
0.96 ~ 3.30 ~ 4.48
5.2 ~ 17.9 ~ 24.3
14 to 118
-13 to +75
Twin Rotary x 1
FVC68D
Propeller
124.2 x 2
2,119 x 2
R410A
2
6
2
56,000
54 / 57
37-13/32 x 54-11/32 x 13
222.7
208 / 230V, 1, 60
4C x 16 / 4C x 18
Ø3/8 x 1
Ø3/4 x 1
197.5
0.54
0.22
475.7
180.4
295.3
49.2
82.0
98.4
49.2
32.8
49.2
MULTI F MAX WITH LGRED | 29