ELECTRICAL CONNECTIONS
Systems for Multi F / Multi F MAX with LGRED
Figure 37: Multi F with LGRED System General Power / Communications System Schematic.
Circuit Breaker
Ground Wiring
Figure 38: Multi F MAX with LGRED System General Power / Communications System Schematic.
Power Supply
Circuit Breaker
Ground Wiring
• Secure the separate wires in the control box panel using zip ties.
• Secure wiring with accessory clamps so that it does not touch the piping.
• Use a conduit for the communications cable / power wiring from the outdoor unit to the indoor / branch distribution units.
• Make sure the communications cable / power wiring from the outdoor units to the indoor / branch distribution units, and the power wiring to
the outdoor unit are separate, otherwise, the outdoor unit operation may be affected by electrical noise and will malfunction or fail.
48 | ELECTRICAL
Power Supply
Outdoor Unit
Outdoor Unit
©
Branch Distribution Unit
Branch Distribution Unit
F
MULTI
WITH
F
MULTI
MAX
Indoor Units
Indoor Unit