When SCKT is checked, a TCP/IP server will be created that will report the record data to any
client that connects to it. To select the details press [...] and the Socket Logging Properties
dialog will be displayed:
IP to allow defaults to 0.0.0.0 which allows any client to connect to the server, any other value
will restrict connections to that IP (a URL may not be used in this field).
IP port selects the TCP port to be used for connecting to the server, and must not conflict with
other TCP ports used by the system (the default value is 52735).
Header interval defines how often a header is output in a separate line before the data record (0
for never, 1 for every time, 2 for ever other time, 3 for every third time, etc). The header
describes the contents of the data record. As long as the Header Interval is not 0, a new header
will be appended after recording has been turned ON to ensure any changes to the setup are
reported.