5 SETTING UP

For all aspects other than serial data transmission the
transmitter is set up as shown in the Operating Instructions
– see Section 1. Unless otherwise requested, the instrument is
despatched with a transmission rate of 9600 baud and
transmission line termination resistors linked-out. If the
resistors are to be linked-in (see Fig. 5.1) carry out the
following section.
5.1 Termination Resistors – Fig. 5.1
For long transmission lines, termination resistors are required
on the last 4600 Transmitter in the chain and at the host
computer/computer
terminal.
conditions the resistors are required at the last 4600 receive
inputs only – see Fig. 4.1. The transmitter's resistors are
selected using plug-in links – see Fig. 5.1.
Switch off the supply and gain access to the processor board
(Section 4 in the Operating Instructions). Set the termination
resistor links as shown in Fig. 5.1.
Under
normal
operating
Processor Board
IC22
IC24
Termination
Termination
Resistors
Resistors
IN
OUT
Fig. 5.1 Termination Resistor Links