Wiring Installation - PDC spas Antero Owners & Installation Manual

Portable spa hot tubs se series; lx series; at series
Table of Contents

Advertisement

W
I
IRING
NSTALLATION
W
G
IRING
UIDELINES
ALL EQUIPMENT MODELS ARE 120/240 VOLT, 60 CYCLE FOR STATE-SIDE, U.S. INSTALLATIONS,
• ALL SPAS MUST BE PERMANENTLY CONNECTED.
• ALL SPA SUPPORT SYSTEMS ARE MULTIPLE SUPPLY CIRCUITS.
• ALL SPA SYSTEMS REQUIRE THE INSTALLATION OF A GROUND FAULT CIRCUIT INTERRUPTER
PROTECTOR (GFCI) OR EQUIVALENT; RCD, FOR EXPORT INSTALLS, AT THE POWER SOURCE
(NOT SUPPLIED) BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL CODES AND
REGULATIONS. REFER TO TYPICAL G.F.C.I. INSTALLATION ON FOLLOWING PAGE.
• PRIOR TO EACH USE, TESTING OF THE GFCI (OR EQUIVALENT) IS REQUIRED. REFER TO THE MAINTE
NANCE SECTION OF THIS MANUAL FOR INSTRUCTIONS.
• ALL SPA SUPPORT EQUIPMENT MUST BE BONDED (GROUNDED) TO THE PRESSURE CONNECTOR
LOCATED WITHIN THE CONTROL PANEL, AS WELL AS THE BONDING TERMINAL LOCATED ON
THE OUTSIDE OF THE CONTROL PANEL. (see wiring schematic below)
• DISCONNECT ALL ELECTRICAL SUPPLIES AND CONTACT A QUALIFIED TECHNICIAN BEFORE SERVICING.
• ALL SPA INSTALLATIONS ARE TO BE PERFORMED BY A LICENSED ELECTRICIAN AND IN ACCORDANCE
WITH ALL LOCAL AND NATIONAL CODES.
O
1
PTION
M
P
AIN
ANEL
C
IRCUIT
G.F.C.I.
O
2
PTION
M
P
AIN
ANEL
C
IRCUIT
* N
ATIONAL
AND 50 HZ FOR EXPORT, CE, INSTALLATIONS.
S
W
S
PA
IRING
CHEMATIC FOR
W
"A"
IRE
B
REAKER
W
"A"
IRE
B
REAKER
U.S.
CODE RECOMMENDS DISTANCE NOT TO EXCEED
33
C
E
' R
ERTIFIED
LECTRICIANS
W
D
ISCONNECT
W
D
ISCONNECT
G.F.C.I.
15
.
FT
O
EFERENCE
NLY
"B" *
IRE
S
PA
"B" *
IRE
S
PA