62
each hex byte to its decimal equivalent. The resulting three decimal
numbers become the FC N-Port (Domain.Area.Port) portion of the primary
boot path:
• 011532 hex
• 01 hex
01 decimal
• 15 hex
21 decimal
• 32 hex
50 decimal
so the FC N-Port portion of the I/O path is 1.21.50.
Composing the entire primary I/O boot path
You can now form the entire primary I/O boot path for PDC by combining:
• the HBA part of the path, 0/6/0/0
• the FC N-Port part of the path, 1.21.50
• your selected SCSI LUN within the disk array, for this example: 0.0.2
(bus.target.lun)
to get the complete primary I/O boot path 0/6/0/0.1.21.50.0.0.2.
Now set the system's primary boot path to that value, and then install the
OS from the SLT tape.
When you are finished loading the OS, return to the main body of this
manual at the "Configure the disk array devices in MPE/iX"
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
01 15 32
(page
31).