Tower kit for H80 Whisper

40 ft
50 ft

Tower installation kit

Tower pipe selection

The tower kit is designed to use 2 ½" pipes .
The following table shows the required thickness of the
pipe(s) depending on the maximum wind speed:
Max. wind speed
[mph]
75
90
110
The wall thickness of the gin pole must be 0.060 in or
greater.
36
Description
30 ft
Tower kit for H80 Whisper
Instructions are included.
Note: The pipes are not included
For tower pipe selection see below.
50 ft
Description
Tower installation kit.
Note: The gin pole is not included
For tower pipe selection see below.
Recommended wall thickness
[in]
0.090
0.120
0.140
Height
30 ft
50 ft
Pieces of pipe needed:
Tower kit, 30 ft
• 1 pipe of 13 ft for tower
• 1 pipe of 17 ft for tower
• 1 pipe of 15 ft for gin pole.
Tower kit, 50 ft
• 2 pipes of 15 ft for tower
• 1 pipe of 20 ft for tower
• 1 pipe of 19 ft for gin pole.
SQFlex
Product no.
96475066
96475067
Product no.
96475069