Alcatel-Lucent 7950 XRS Series Configuration Manual page 481

Extensible routing system sr os basic system
Table of Contents

Advertisement

Reference BITS A
Admin Status
Rx Quality Level
Quality Level Override
Qualified For Use
Selected For Use
Interface Type
Framing
Line Coding
Line Length
Output Admin Status
Output Admin State
Output Source
Output Reference Selected
Tx Quality Level
======================================================================
The following example is for a node whose standby CPM is locked to its local BITS port and the signal from
ref1 is directed to the BITS output port:
A:SR7# show system sync-if-timing standby
===============================================================================
System Interface Timing Operational Info
===============================================================================
System Status CPM B
Reference Input Mode
Quality Level Selection
Reference Selected
System Quality Level
Current Frequency Offset (ppm) : +0
Reference Order
Reference Mate CPM
Qualified For Use
Selected For Use
Reference Input 1
Admin Status
Rx Quality Level
Quality Level Override
Qualified For Use
Selected For Use
Source Port
Reference Input 2
Rx Quality Level
Quality Level Override
Qualified For Use
Selected For Use
Source Port
7950 SR OS Basic System Configuration Guide
Not Qualified Due To
Not Selected Due To
Not Selected Due To
Not Qualified Due To
Not Selected Due To
Not Qualified Due To
Not Selected Due To
: up
: unknown
: none
: No
: LOS
: No
: not qualified
: DS1
: ESF
: B8ZS
: 550-660ft
: up
: ref1
: prs
: ptp
: prs
: Master Locked
: Non-revertive
: Disabled
: BITS B
: prs
: bits ref1 ref2
: Yes
: No
: on standby
: down
: unknown
: none
: No
: disabled
: No
: disabled
: None
: unknown
: none
: No
: disabled
: No
: disabled
: None
Show Commands
Page 481

Advertisement

Table of Contents
loading

Table of Contents