Select Calibration Table; Manual Geometry Alignment - Mitsubishi Electric WD-73640 Technical Training Manual

Hide thumbs Also See for WD-73640:
Table of Contents

Advertisement

Select Calibration Table

1. In the Customer's Video Settings Menu select COLOR TEMP: HIGH
2. Enter the Service Menu <MENU-<2-4-5-7>.
3. Use the <VIDEO> button to select the adjustment, "61.BCMH" and note the data value (0, 1, 2, 3 or 4).
4. Select the Green Double Ramp Pattern by pressing PLAY <  > twice, then FAST FORWARD <  > or
REWIND <  > until the pattern below appears.
5. Check the pattern for smoothness of graduation from dark to light and for the presence any vertical contour
lines.
6. Use the DIRECTION <  > buttons to alternately change the Data Value of "61.BCMH" to 0, 1, 2, 3 or 4.
As necessary, press PLAY <  > once to observe the Service Menu on screen display and press PLAY <  >
twice to return to the pattern.
7. Select the data value 0, 1, 2, 3 or 4 that gives the best results. No higher data value should be used.
8. Press <ENTER> to save the adjustment.

Manual Geometry Alignment

1. Activate the Service Mode <MENU><2-4-5-7>. From the Service Menu, press the <0> button. The Data Trans-
fer & Geometry Menu will appear.
2. Use the <  > buttons to select "MANUAL GEOMETRY ALIGNMENT" and press <ENTER>.
3. The Manual Geometry Alignment Pattern will appear. See below.
4.
Prepare for the alignment by resetting the geometry data. Press <1> then <ENTER>. The previous menu will be
displayed. Select "MANUAL GEOMETRY ALIGNMENT" and press <ENTER> again to proceed.
Note 1:
Upon entering the Manual Geometry Alignment Mode the first time, the geometry may appear distorted
because all factory geometry correction is automatically disabled. Press <EXIT> to quit and re-enable
the factory geometry correction. Pressing <1> <ENTER> and <EXIT> will cause the TV to operate with
out factory geometry correction (distortion will be present).
Note 2:
At any time the original factory geometry data can be restored from backup:

From the Data Transfer & Geometry Menu <MENU><2-4-5-7><0>, select "RESTORE GEOMETRY
DATA FROM BACKUP" <ENTER>.
(after Light Source Unit replacement)
Before
Adjustment
After
Adjustment
31