Led Indications And Self Diagnostics; Normal Indications; Abnormal Indications; Self Diagnostics - Mitsubishi Electric WD-73640 Technical Training Manual

Hide thumbs Also See for WD-73640:
Table of Contents

Advertisement

The front panel Power LED provides an indication of the set's operation and the possible cause of a malfunction.
STATUS LED Indication
Off
Green
Slow Blinking Green
Fast Blinking Green 1 to 3 minutes after Power
Restored from AC interrupt, Power On, System
Reset or Software update.
STATUS LED Indication
Blinking Red then Blinking Yellow

SELF DIAGNOSTICS

A blinking red and yellow Status LED will indicate an Error Code that can help determine the cause of a circuit
failure.

The number of Red blinks indicates the value of the MSD (tens digit) of the Error Code.

The number of Yellow blinks indicates the value of the LSD (ones digit) of the Error Code.
Example: If the Error Code is "37", the LED will continuously blink Red three times, followed by blinking Yellow
seven times.
See the following page for a list of Error Codes.
To perform a System Reset, press and hold the Power button for 10 seconds. Or, unplug the set for 10 seconds
then restore power.

LED INDICATIONS AND SELF DIAGNOSTICS

NORMAL INDICATIONS

ABNORMAL INDICATIONS

Number of Red Blinks  Number of Yellow Blinks

3
Error Code: 37
Condition
Off (Standby)
Power On
Power Off with Timer Set. Power On normally
Boot-up. Wait for blinking to stop to Power On.
Condition
Circuit Failure (See Self Diagnostics)

7
26