Parameter Group C - Omron 3G3JX Quick Start Manual

200 v class three-phase input 0.2 to 7.5 kw; 200 v class single-phase input 0.2 to 2.2 kw; 400 v class three-phase input 0.4 to 7.5 kw
Hide thumbs Also See for 3G3JX:
Table of Contents

Advertisement

PARAMETER LIST

4.4 Parameter group C

Parameter
Function name
No.
C001
Multi-function input 1 selection
C201
2nd multi-function input 1 selection
C002
Multi-function input 2 selection
C202
2nd multi-function input 2 selection
C003
Multi-function input 3 selection
C203
2nd multi-function input 3 selection
C004
Multi-function input 4 selection
C204
2nd multi-function input 4 selection
C005
Multi-function input 5 selection
C205
2nd multi-function input 5 selection
C011
Multi-function input 1 operation selection
C012
Multi-function input 2 operation selection
C013
Multi-function input 3 operation selection
C014
Multi-function input 4 operation selection
C015
Multi-function input 5 operation selection
C021
Multi-function output terminal 11 selection
C026
Relay output (AL2, AL1) function selection
C028
AM selection
C031
Multi-function output terminal 11 contact
selection
C036
Relay output (AL2, AL1) contact selection
C038
Light load signal output mode
C039
Light load detection level
C041
Overload warning level
C241
2nd overload warning level
C042
Arrival frequency during acceleration
C043
Arrival frequency during deceleration
C044
PID deviation excessive level
C052
PID FB upper limit
C053
PID FB lower limit
C070
Operator/Modbus selection
C071
Communication speed selection (Baud rate
selection)
C072
Communication station No. selection
JX Quick Start Guide
Monitoring or data range (digital operator)
00: FW (forward)
01: RV (reverse)
02: CF1 (multi-step speed setting binary 1)
03: CF2 (multi-step speed setting binary 2)
04: CF3 (multi-step speed setting binary 3)
05: CF4 (multi-step speed setting binary 4)
06: JG (jogging)
07: DB (external DC injection braking)
08: SET (2nd control)
09: 2CH (2-step acceleration/deceleration)
11: FRS (free-run stop)
12: EXT (external trip)
13: USP (USP function)
15: SFT (soft lock)
16: AT (analog input switching)
18: RS (reset)
19: PTC (thermistor input)
20: STA (3-wire start)
21: STP (3-wire stop)
22: F/R (3-wire forward/reverse)
23: PID (PID enabled/disabled)
24: PIDC (PID integral reset)
27: UP (UP/DWN function accelerated)
28: DWN (UP/DWN function decelerated)
29: UDC (UP/DWN function data clear)
31: OPE (forced operator)
50: ADD (frequency addition)
51: F-TM (forced terminal block)
52: RDY (ready function)
53: SP-SET (special 2nd function)
*1
64: EMR (emergency shutoff
)
255: No function
*1. The EMR is set forcibly with switch S8, not with parameters.
00: NO
01: NC
00: RUN (signal during RUN)
01: FA1 (constant speed arrival signal)
02: FA2 (over set frequency arrival signal)
03: OL (overload warning)
04: OD (excessive PID deviation)
05: AL (alarm output)
06: Dc (disconnection detection)
07: FBV (PID FB status output)
08: NDc (network error)
09: LOG (logic operation output)
10: ODc (do not use)
43: LOC (light load detection signal)
00: Output frequency
01: Output current
00: NO contact at AL2, NC contact at AL1
01: NC contact at AL2, NO contact at AL1
00: Enabled during acceleration/deceleration/constant
speed
01: Enabled only during constant speed
0.0 to 2.0 x Rated current (0.0 setting: function disable)
0.0: Does not operate
0.1 x Rated current to 2.0 x Rated current
0.0 to 400.0
0.0 to 100.0
0.0 to 100.0
02: Digital Operator
03: Modbus
04: 4800 bps
05: 9600 bps
06: 19200 bps
1. to 32.
Changes
Default
during
Unit
setting
operation
00
No
00
01
01
18
18
12
12
02
02
00
No
00
No
05
00
No
00
No
01
01
No
Rated
No
current
Rated
No
A
current
0.0
No
Hz
3.0
No
%
100.0
No
%
0.0
02
No
04
No
1.
No
Modbus
address
(hex)
1103
1532
1104
1533
1105
1534
1106
1535
1107
1536
110B
110C
110D
110E
110F
1114
1119
111B
111D
1122
1178
1179
1124
153A
1126
1128
1129
112E
112F
1137
1137
1139
31