Starting The Unit; Light Operation - Generac Mobile Products MLT6SK Operating Manual

Light tower
Table of Contents

Advertisement

Operation
4. Rotate the mast by loosening the mast rotation knob at the bottom of the mast (D). Turn the mast until the
lights face in the desired direction and then tighten the mast rotation knob to secure the mast in position.

STARTING THE UNIT

Note: If the engine was run out of fuel or the fuel tank was drained, it may be necessary
to bleed the fuel lines. Refer to the engine operator's manual supplied with the unit.
5. Check that the main circuit breaker(s) are in the OFF (O) position.
6. Turn the key on the Control Power switch to the right Glow Plug (
tion and hold the key in place for five seconds, then turn the key to the right
Start (
) position and hold it until the engine cranks and starts running.
Release the key, it will move to the Run (
Note: For cold weather conditions, refer to the engine operator's manual for appropriate glow plug interval.
ACTIVATE GLOW PLUGS
STOP
Do not crank the engine longer than 10 seconds at a time. If the engine will not start, wait
30 seconds to allow the starter motor to cool and then repeat the starting procedure.
Note: If oil pressure is not obtained within 15 seconds after the key is switched to the Run (
automatic shutdown will turn off the fuel supply, stopping the engine. Check the oil level and turn the key to the Stop
(
) position to reset the oil pressure timer before attempting to restart the engine.
STOP
7. Once the engine is running, allow it to reach normal operating temperature before switching on any loads.

LIGHT OPERATION

NEVER operate the lights without the protective lens cover, or with a lens cover that
is cracked or damaged. The bulbs in the light fixtures produce high temperatures and
operate under pressure. A broken or missing lens cover could cause the bulbs to
20
Never raise or lower the mast while the unit is operating.
CRANK ENGINE TO START
15 SEC.
MAX.
Figure 11 - Key Locations to Starting the Unit
Excessive cranking will cause damage to the starter.
shatter, causing injury.
MLT6SM/K-8SK Operating Manual
WARNING
) position.
15 SEC.
MAX.
STOP
WARNING
I
O
MAIN
BREAKER
) posi-
240V
I
O
Figure 10 - Direction of
Switches
RELEASE KEY
15 SEC.
MAX.
STOP
00760
) position, the low oil
I
I
O
O
I
I
O
O
00759
17973 G