Suds cooling

When this is activated, additional wa-
ter flows into the drum at the end of
the main wash to cool the suds down.
Hot suds can damage plastic drainage
pipes.
Suds cooling takes place when a tem-
perature of 70 °C or higher is selected
for the Cottons programme.
Suds cooling should be activated:
– to prevent the danger of scalding if
the drain hose is hooked over the
edge of a sink or basin.
– where drainage pipes do not comply
with DIN 1986.
Factory default setting: Suds cooling is
switched off.

Low water pressure

If the water pressure is less than 1 bar
(100 kPa) the programme will be can-
celled and the fault message
take fault
will appear.
If the on-site water pressure cannot be
increased, activating this function will
prevent the programme from being can-
celled.
Factory default setting: Low water pres-
sure is switched off.

Delay start

For specifying which time prompt
should appear with the delay start
function.
Options
– Start at
With the Delay start function you
specify at what time the wash pro-
gramme should begin.
– Finish at (Factory default setting)
With the Delay start function you
specify at what time the wash pro-
gramme should end.

Anti-crease

The anti-crease function helps prevent
creasing if laundry is not going to be
removed immediately after the end of
the programme.
The drum continues to turn at intervals
for up to 30 minutes at the end of the
programme. The door can be opened at
Water in-
any time.
Factory default setting: anti-crease is
switched on.