Camera Power Connections; Heater Connections - Roughneck V910A-WDR Installation & Operation Manual

V910 impact-resistant dome cameras with wide dynamic range
Table of Contents

Advertisement

Note: Vicon systems and components, like most electronic equipment, require a clean, stable power source.
Voltage irregularities such as surges, drops, and interruptions can affect the operation of your
equipment and, in severe cases, damage certain components.
Power (24 VAC) is connected through a two-position terminal connector on the PC board (TB1 on coax/UTP,
J2 on fiber). Refer to Table 2 for the input power connections.
Note: Use only a UL Listed Class 2 indoor/dry or Class 3 outdoor/wet rated power supply.
1. Locate the power cable terminal on the PC board.
2. Strip approximately 1 in. (25 mm) of insulation off power cables. Then strip off approximately 0.25 in.
(6 mm) of insulation off each individual wire. Refer to Figure 6. Connect the wire into the terminal block.
Repeat for each connection. Refer to Table 2.
3. Connect the terminal block onto the board connector.
The camera is shipped prepared for 24 VAC.
Note: A grounding tab is provided on the PC board for those installations requiring a ground. The use of the
ground tab to earth ground is necessary to provide protection to the camera. A Faston (lug) is provided
in the accessory kit.
The V910 has a heater in the base. Refer to Figure 1. The unit is delivered with the heater connection made
to the connector (P4 on coax/UTP, J1 on fiber) on the PC board. Refer to Figure 5A or 5B, depending on
version.
8 • 5BInstallation
Camera/Lens PC Board (Fiber version)

Camera Power Connections

Figure 6
Cable Preparation
Table 2
Camera Power Connections
Pin Number
1
2

Heater Connections

XX137-60-00 Rev 109 Roughneck V910 Dome Cameras with WDR
Function
24 VAC
24 VAC Return

Advertisement

Table of Contents
loading