Roughneck V894CSH Installation & Operation Manual

Corner-mounted series of high-security cameras
Hide thumbs Also See for V894CSH:

Advertisement

Quick Links

MODEL V894CSH CORNER-MOUNTED
SERIES OF HIGH- SECURITY CAMERAS
Copyright © 2010 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice
Vicon and its logo are registered trademarks of Vicon Industries Inc.
Loctite is a trademark of Loctite Corporation.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-2288
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: 44 (0) 1489 566300
Vicon part number 8006-8935-25-00
FAX: 631-951-2288
TOLL FREE: 800-645-9116
WEB: www.vicon-security.com
X935-25-00
Rev 1110

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V894CSH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Roughneck V894CSH

  • Page 1 Copyright © 2010 Vicon Industries Inc. All rights reserved. Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc. Loctite is a trademark of Loctite Corporation. VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788...
  • Page 3: Fcc Notice

    Warning: Power must be removed from this unit before removing circuit modules or ribbon cables. Caution: This unit contains circuit cards with integrated circuit devices that can be damaged by static discharge. Take all necessary precautions to prevent static discharge. FCC Notice • i X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 4: Table Of Contents

    Lens/Autoiris Adjustment ........................... 11   Camera Positioning ............................ 11   Final Installation Steps ..........................12 Maintenance ........................12   Shipping Instructions ....................... 12   Coaxial Cable Recommendations ................... 13   Technical Information ...................... 14   Vicon Standard Equipment Warranty ................17  ...
  • Page 5 8. Accessories - Do not place the unit on an unstable surface power supply is intended to serve as the disconnect device, to avoid falling. Use only UL Listed Vicon recommended mounting follow the guidelines below: accessories.
  • Page 7: Introduction

    Introduction The information in this manual provides installation and maintenance procedures for the V894CSH Corner- Mounted Series of High-Security Camera/Housings. These units should only be installed by a qualified technician using approved materials in conformance with federal, state, and local codes. Read these instructions thoroughly before beginning an installation.
  • Page 8: Installation

    Physical Installation The V894CSH series is designed to fit into a corner where two walls and a ceiling meet. It may be fastened to either or both walls or to the walls and the ceiling. Refer to Figure 1. Cable access is provided on one side.
  • Page 9 Tool for set screw roll adjustment Table 2: Accessory Pack Contents Required tool: The Torx bit that is supplied is designed for a socket or screwdriver-type holder designed for hexagonal bits. Installation • 3 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 10: Mounting The Housing

    A UL listed Class 2 power supply with 24 VAC is required for powering the V894CSH camera. Connect the power cables from the camera to the power source; red is + (plus) and black is – (minus). Push excess wires through the grommet and arrange in housing as required.
  • Page 11: Camera/Lens Adjustments

    (Right direction is marked.) A indicates submenus. Below is a summary of the OSD screens for camera setup of the day/night version. An explanation of the individual screens follows. Installation • 5 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 12 9. E X IT MIRROR EXIT SHARPNESS SAVE & EXIT GAMMA FACTORY SET FREEZE NEGA 3D_DNR D_ZOOM 5. M OTION MOTION SET WINDOW ALL SET ALL CLEAR SENSITI SHOW INDI DELAY OUT 6 • Installation X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 13 White Balance can be directly adjusted by user in Manual mode. In that case, select R-Y or B-Y Gain to adjust the value of Red and Blue Gain (125 is default). Installation • 7 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 14 Digital Zoom can be turned ON or OFF (default). When ON, there are settings for digital zooming up to 3X, setting pan and tilt positions (left/right or up/down) and turning ON or OFF a display of the PTZ amounts. 8 • Installation X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 15: Privacy Mask

    Privacy masks can be turned ON or OFF (default). When turned ON, the mask range is used to shape and locate the mask on the screen. One of eight colors of the mask can be selected. Installation • 9 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 16 Select language from ENGLISH (default) or KOREAN. Baud Rate Select the data communication speed from 2400, 4800, 9600 (default), 14400, 19200 or 38400. Omni Lens This camera does not support the Omni lens at this time. 10 • Installation X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 17: Lens/Autoiris Adjustment

    The picture may be “squared up” by rotating the camera about its own axis up to 360° (roll adjustment). Note: After all adjustments are made, be sure to tighten all bracket screws. Installation • 11 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 18: Final Installation Steps

    Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
  • Page 19: Coaxial Cable Recommendations

    Coaxial Cable Recommendations Caution: Careful selection of proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended, or equivalent, are installed. In all cases, coaxial cable impedance should be 75 ohms.
  • Page 20: Technical Information

    (lens may be rotated on its axis 360º). Lens Adjustment: Focus: focus lever screw. Zoom: zoom lever screw. OPTICAL Light Loss through Window: Negligible. Camera/Lens Specifications: Refer to Table 3. 14 • Technical Information X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 21 32° to 122° F (0° to 50° C). Operating Humidity Range: 0 to 90% relative, non-condensing. Storage Temperature Range: -40° to 150° F (-40° to 60° C). Storage Humidity Range: 0 to 90% relative, non-condensing. Technical Information • 15 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 22 PAL: 1/50-1/100,000 sec Lens Focal Length 3.3 - 12 mm varifocal 2.6 - 6 mm varifocal Field-of View (degrees) Horiz: 83.9-23.91 Horiz: 106-47.6 Vert: 61.9-17.93 Vertical: 78.2 -35.8 Table 3: Camera/Lens Specifications 16 • Technical Information X935-25-00 Rev 1110 V894CSH High-Security Cameras...
  • Page 23: Vicon Standard Equipment Warranty • 17

    Vicon Security Management Systems (SMS) All Models: All hardware is warranted for two years from date of original retail purchase. Any product sold as “special” or not listed in Vicon’s commercial price list: One year from date of original retail purchase.
  • Page 24 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-2288 800-645-9116 Fax: 631-951-2288 Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom +44 (0) 1489 566300 Fax: +44 (0) 1489 566322 Vicon Germany Kornstieg 3 D-24537 Neumuenster...

Table of Contents