Warning: Power must be removed from this unit before removing circuit modules or ribbon cables. Caution: This unit contains circuit cards with integrated circuit devices that can be damaged by static discharge. Take all necessary precautions to prevent static discharge. FCC Notice • i X935-25-00 Rev 1110 V894CSH High-Security Cameras...
Lens/Autoiris Adjustment ........................... 11 Camera Positioning ............................ 11 Final Installation Steps ..........................12 Maintenance ........................12 Shipping Instructions ....................... 12 Coaxial Cable Recommendations ................... 13 Technical Information ...................... 14 Vicon Standard Equipment Warranty ................17 ...
Page 5
8. Accessories - Do not place the unit on an unstable surface power supply is intended to serve as the disconnect device, to avoid falling. Use only UL Listed Vicon recommended mounting follow the guidelines below: accessories.
Introduction The information in this manual provides installation and maintenance procedures for the V894CSH Corner- Mounted Series of High-Security Camera/Housings. These units should only be installed by a qualified technician using approved materials in conformance with federal, state, and local codes. Read these instructions thoroughly before beginning an installation.
Physical Installation The V894CSH series is designed to fit into a corner where two walls and a ceiling meet. It may be fastened to either or both walls or to the walls and the ceiling. Refer to Figure 1. Cable access is provided on one side.
Page 9
Tool for set screw roll adjustment Table 2: Accessory Pack Contents Required tool: The Torx bit that is supplied is designed for a socket or screwdriver-type holder designed for hexagonal bits. Installation • 3 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
A UL listed Class 2 power supply with 24 VAC is required for powering the V894CSH camera. Connect the power cables from the camera to the power source; red is + (plus) and black is – (minus). Push excess wires through the grommet and arrange in housing as required.
(Right direction is marked.) A indicates submenus. Below is a summary of the OSD screens for camera setup of the day/night version. An explanation of the individual screens follows. Installation • 5 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
Page 12
9. E X IT MIRROR EXIT SHARPNESS SAVE & EXIT GAMMA FACTORY SET FREEZE NEGA 3D_DNR D_ZOOM 5. M OTION MOTION SET WINDOW ALL SET ALL CLEAR SENSITI SHOW INDI DELAY OUT 6 • Installation X935-25-00 Rev 1110 V894CSH High-Security Cameras...
Page 13
White Balance can be directly adjusted by user in Manual mode. In that case, select R-Y or B-Y Gain to adjust the value of Red and Blue Gain (125 is default). Installation • 7 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
Page 14
Digital Zoom can be turned ON or OFF (default). When ON, there are settings for digital zooming up to 3X, setting pan and tilt positions (left/right or up/down) and turning ON or OFF a display of the PTZ amounts. 8 • Installation X935-25-00 Rev 1110 V894CSH High-Security Cameras...
Privacy masks can be turned ON or OFF (default). When turned ON, the mask range is used to shape and locate the mask on the screen. One of eight colors of the mask can be selected. Installation • 9 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
Page 16
Select language from ENGLISH (default) or KOREAN. Baud Rate Select the data communication speed from 2400, 4800, 9600 (default), 14400, 19200 or 38400. Omni Lens This camera does not support the Omni lens at this time. 10 • Installation X935-25-00 Rev 1110 V894CSH High-Security Cameras...
The picture may be “squared up” by rotating the camera about its own axis up to 360° (roll adjustment). Note: After all adjustments are made, be sure to tighten all bracket screws. Installation • 11 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
Coaxial Cable Recommendations Caution: Careful selection of proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended, or equivalent, are installed. In all cases, coaxial cable impedance should be 75 ohms.
(lens may be rotated on its axis 360º). Lens Adjustment: Focus: focus lever screw. Zoom: zoom lever screw. OPTICAL Light Loss through Window: Negligible. Camera/Lens Specifications: Refer to Table 3. 14 • Technical Information X935-25-00 Rev 1110 V894CSH High-Security Cameras...
Page 21
32° to 122° F (0° to 50° C). Operating Humidity Range: 0 to 90% relative, non-condensing. Storage Temperature Range: -40° to 150° F (-40° to 60° C). Storage Humidity Range: 0 to 90% relative, non-condensing. Technical Information • 15 X935-25-00 Rev 1110 V894CSH High-Security Cameras...
Vicon Security Management Systems (SMS) All Models: All hardware is warranted for two years from date of original retail purchase. Any product sold as “special” or not listed in Vicon’s commercial price list: One year from date of original retail purchase.