1) General
This section provides information and instructions for removal and installation of the exciter armature
used on this generator set. Through design improvements, the exciter and rear main bearing can be
removed without removing the generator from the generator set. The name "exciter armature" refers to
the shaft-mounted, revolving, three-phase windings of the exciter.
1. Coupling Key (Not Shown)
2. Flex Coupling Assembly
3. Generator Housing & Stator Assembly
4. Armature Assembly
5. Exciter Housing & Coils Assembly
May 2, 2013
Exciter Armature
General Assembly
6. Exciter Cover
7. Exciter Armature Assembly
8. Exciter Key (Not Shown)
9. Front Bearing (Located Inside Housing Shown)
10. Rear Bearing (Located In Exciter Housing)
Figure 1