Hobart 60CU20 Operation And Maintenance Manual With Illustrated Parts List page 73

60 kva, 3 phase, 115/200 volt, 400 hz. generator set. series 500062
Table of Contents

Advertisement

OM-2226 / Operation and Maintenance Manual
60CU20 / Series 500062 / 400 Hz. Generator Set
Symbol
1
Grease, General Purpose
e) Engine Accessories Lubrication
(1) Alternator
Most alternators contain sealed bearings and require no periodic lubrication, however, check to
make certain there are no lubrication points on your particular alternator.
(2) Starter
Most starting motors are lubricated at assembly and should be re-lubricated only when the starter
is removed and disassembled, however, inspect the starter to make certain it has no lubrication
points.
(3) Water Pump
The water pump is packed at assembly and requires no periodic lubrication. Replace pump if
signs of lubricant leakage are found.
(4) Fan Pulley
The fan hub is also lubricated at assembly and requires no periodic lubrication. Replace hub if
lubricant is leaking.