Tampering Alarm; Dip Switches - Axis A4011-E Installation Manual

Table of Contents

Advertisement

Wire Area
NO TICE
TICE
NO
NO
TICE
Each wire shall have an area that corresponds to an conductor gauge range of
AWG 28–16 (CSA) or AWG 22–14 (cUL/UL). Select cables in compliance with your local
regulations.
AWG
28–16
22–14

Tampering Alarm

The tampering alarm switch and tampering alarm sensor can toggle between an open and closed
circuit. When the reader is removed from the surface it is attached to, or when the frontplate is
removed, an alarm event is sent to the door controller. In the door controller, the alarm event can
be used to trigger an action. For information, see the door controller's User Manual.

DIP Switches

The reader can be configured through eight DIP switches that are located on the right side of the
circuit board. To change the configuration, remove the frontplate, and then flip the DIP switches
as required. For information about card formats and reader feedback, see the door controller's
User Manual.
DIP
Default setting
1
OFF
2
OFF
3
OFF
4
OFF
5
OFF
6
OFF
7
OFF
8
OFF
Diameter mm (in)
0.321–1.29 (0.0126–0.0508)
0.644–1.63 (0.0253–0.0641)
Function
Address value 1
Address value 2
Address value 4
Key beep: beep at keystrokes and major/minor signal
at invalid/valid card
Card beep: beep at card read
n/a
Light on: keypad always lit
Light code: keypad lits when the indication for PIN code
is activated
AXIS A4011-E Reader
9
2
Area mm
0.0810–1.31
0.326–2.08