Instructions for Installation (cont'd)
Venting
(cont'd)
VENTING THROUGH AN OUTSIDE WALL (cont'd)
* The water heater requires its own (separate) venting system.
75 GALLON 70,000 AND 75,000 BTU/HR MODELS
ONLY
* 4" and Y' PVC, ABS or CPVC Schedule 40 piping and fit-
tings are acceptable materials for the vent system on all 75
• The water heater requires its own (separate) venting system,
gallon 70,000 and 75,000 BTU/HR models.
• 3" PVC, ABS or CPVC Schedule 40 piping and fittings are
° It cannot be connected to existing vent piping or chimney.
acceptable materials for the vent system on all 75 gallon
70,000 and 75,000 BTU/HR
models.
• It must terminate horizontally to the outdoors.
• It cannot be connected to existing vent piping or chimney.
ALL 40 AND 50 GALLON 40,000 BTU/HR MODELS
• It must terminate horizontally to the outdoors.
ONLY
3" PVC, ABS or CPVC Schedule 40 vent piping:
75 GALLON 70,000 AND 75,000 BTU/HR MODELS
ONLY -- OPTIONAL 4" VENT PIPING
• A 3" PVC Schedule 40-45 ° vent cap with wire screen is
4" PVC, ABS or CPVC Schedule 40 vent piping:
supplied with the water heater.
• A 3" PVC, ABS or CPVC Schedule 40-90 ° street ell; used
• A wire screen to fit a 4" PVC, ABS or CPVC Schedule 40-
to connect the vent pipe to the water heater when the vent
45* vent cap is supplied with the water heater,
pipe is to be turned horizontally directly offthe blower (sup-
• A 4" PVC, ABS or CPVC Schedule 40-45 ° vent cap
plied locally).
(must be supplied locally).
• 3" PVC, ABS or CPVC Schedule 40 pipe (must be sup-
* A 3" PVC, ABS or CPVC Schedule 40 pipe, minimum
plied locally).
length of 3" (must be supplied locally), to make vent con-
nection at the blower outlet.
3" PVC, A BSORCPVC
SCHEDULE L-_
• A 4" to 3" PVC, ABS or CPVC Schedule 40 reducer (must
40 90°
EL,OWr J I I
I
be supplied locally).
3" PVC, A BSORCPVC
SCHEDULE 40 PIPE
VENTCAP
• A 4" PVC, ABS or CPVC Schedule 40-90 °
street
ell; used
_
WITHSCREEN
to connect the vent pipe to the reducer when the vent pipe is
to be turned horizontally offthe blower (supplied locally).
_
I
• 4" PVC, ABS or CPVC Schedule 40 pipe (must be sup-
plied locally).
• The water heater requires its own (separate) venting
system.
4" PVC, A BS ORCPVC
4" PVC, A BS ORCPVC
SCHEDULE
40 PiPE
• 3" PVC, ABS or CPVC Schedule 40 piping and fittings
SCHEDULE
4090°/_-_
t
,,
[
]
_
are acceptable materials for the vent system on all 40 and
STREET ELBOW
50 gallon 40,000 BTU/HR models.
4"VENT CAP
[_4"
TO3" PVC, A BS OR
CPVC REDUCER
WITHSCREEN
• It cannot be connected to existing vent piping or
_]
3"PVC, A BSORCPVC SCHEDULE 40
chimney.
PIPE (MINIMUMLENGTH 3 ")
• It must terminate horizontally to the outdoors.
t
i
20