Temperature-Pressure Relief Valve - Maytag HJ640NOVET User Manual

Power vent gas water heater
Table of Contents

Advertisement

Instructions for Installation (cont'd)
Temperature-Pressure
Relief Valve
_WARNING
AWARNING
At the time of manufacture this water heater was provid-
The temperature-pressure relief valve must be manu-
ed with a combination temperature-pressuresrelief valve
all)' operated at least once a year. Caution should be
certified by a nationally recognized testing laboratory that
taken to ensure that (1) no one is in front of or
maintains periodic inspection of production of listed
around the outlet of the temperature-pressure relief
equipment or materials, as meeting the requirements for
valve discharge line, and (2) the water manually dis-
Relief Valves and Automatic Gas Shutoff Devices for Hot
charged will not cause any bodily injury or property
Water Supply Systems, and the latest edition of ANSI
damage because the water may be extremely hot.
Z21.22 and the code requirements of ASME. If replaced,
If after manually operating the valve, it fails to com-
the valve must meet the requirementsof local codes,but
pletely reset and continues to release water, immedi-
not less than a combination temperature and pressure
ately close the cold water inlet to the water heater,
relief valve certified as meeting the requirements for
follow
the draining
instructions, and replace the
Relief Valves and Automatic Gas Shutoff Devices for Hot
temperature-pressure relief valve with a new one.
Water Supply Systems,ANSI Z21.22 by a nationally recog-
nized testing laboratory that maintains periodic inspection
of productionof listed equipment or materials.
The valve must be marked with a maximum set pressure
not to exceed the marked hydrostaticworking pressureof
the water heater (150 Ibs./sq. in.) and a dischargecapacity
not lessthan the water heater input rate as shown on the
model rating plate. (Electric heaters - watts divided by
1000 x 3415 equal BTU/Hr.rate.)
COLD
Your local jurisdictional authority, while mandating the
use of a temperature-pressure relief valve complying with
ANSI Z21.22 and ASME, may require a valve model differ-
ent from the one furnished with the water heater.
TEMPERATURE-PRES-
Compliancewith suchlocal requirements must be satisfied
/
SURE REUEF V ALVE
by the installer or end user of the water heater with a
/f
Iocallyprescribed
temperature-pressure
relief valve
installed in the designated opening in the water heater in
place of the factory furnishedvalve.
HOT
For safe operation of the water heater, the relief valve
must not be removed from it's designated opening or
--
DISCHARGE PIPE
lugged.
(Do not capor plug)
_perature-pressure relief valve must be installed
PROVIDE A 6" AIR
into the fitting of the water heater designatedfor
GAPBETWEEN THE
'alve. Positionthe valve downward and provide
ENDOFTHE
DISCHARGE PIPE
tubing so that any dischargewill exit only within 6 inches
ANDDRAIN
above, or at any distance below the structural floor. Be
certain that no contact is made with any live electrical
part. The discharge opening must not be blocked or
reduced in size under any circumstances. Excessivelength,
over 30 feet, or use of more than four elbows can cause
restriction and reducethe dischargecapacity of the valve.
No valve or other obstruction is to be placed between the
relief valve and the tank. Do not connect tubing directly to
RELIEF
VALVE
OPENING
dischargedrain unlessa 6" air gap is provided. To prevent
bodily injury, hazard to life, or property damage, the relief
"THIS WATER HEATER
IS APPROVED
WITH A COMBINATION
TEMPERATURE-
PRESSURE
RELIEF VALVE. FOR SAFE OPERATION
OFTHE WATER H EATER,
valve must be allowed to discharge water in quantities
THERELIEF VALVE(S) MUST NOT BEREMOVED FROM ITS DESIGNATED
shouldcircumstances demand. If the dischargepipe is not
POINT OFiNSTALLATiON
OR PLUGGED."
connected to a drain or other suitable means, the water
YOUR LOCAL JURISDICTIONAL
AUTHORITy,
WHILE MANDATING
THE USE
flow may causeproperty damage.
OFA TEMPERATURE-PRESSURE
RELIEF VALVE C OMPLYING
WITH ANSi
The DischargePipe:
z21.22 AND ASME, MAY REQUIRE
AVALVE M ODEL DIFFERENT
FROM THE
• Must notbe smaller in size than the outlet pipe size of
ONE FURNISHED
WITH THE WATER HEATER.
the valve, or have any reducing couplings or other
COMPLIANCE
WITH SUCH LOCAL REQUIREMENTS
MUST BESATISFIED
BY
restrictions.
THE INSTALLER
OREND USER O FTHE WATER H EATER WITH A LOCALLY
PRESCRIBED
TEMPERATURE-PRESSURE
RELIEF VALVE I NSTALLED
INTHE
• MUStnot be plugged or blocked.
DESIGNATED
OPENING
INTHE WATER HEATER.
• Must be of material listedfor hot water distribution.
SEE MANUAL H EADING - "TEMPERATURE-PRESSURE
RELIEF
VAWES" FOR
• Must be installed so as to allow complete drainage of
INSTALLATION
ANDMAINTENANCE
OFRELIEF VALVE, DISCHARGE
LINE
both the temperature-pressurerelief valve, and the dis-
AND OTHER SAFETY
PRECAUTIONS.
chargepipe.
• Must terminate at an adequate drain.
• Must not have any valve between the relief valve and
tank.
16