WIRED REMOTE CONTROLLER BUTTONS
N
. o
1
2
6
3
4
5
7
8
4+2
3+6
2+6
4+6
5+7
5+7
1
Enter/Cancel
Enter/cancel
Function
5
Fig. 4 - Wired Remote Controller Buttons
WIRED REMOTE CONTROLLER BUTTON FUNCTIONS
Table 2—Controller Button Functions
N
a
m
e
Enter/Cancel
Function selection and cancellation
Running temperature setting of the indoor unit, range:
Timer setting, range:0.5-24 hr
Fan
Setting of the high/middle/low/auto fan speed
Mode
Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit
Function
Switchover among the functions of Turbo/Save/E-heater/Blow etc.
Timer
Timer setting
On/Off
Turn on/off the indoor unit
Press for 5s under the unit's OFF state to Enter/Cancel the Memory
function (If the memory is set, t h e indoor unit after a power failure and
power recovery resumes the original setting state. If not, the indoor
unit defaults to OFF after a power recovery. MEMORY OFF is t h e
default prior to delivery).
Press at the same time under the unit's OFF state,
wired remote controller for the COOLING ONLY unit, while
the wired remote controller for the cooling and heating unit.
Upon u n i t startup ( without malfunction) or under t h e u n i t ' s OFF state,
press both at the same time for 5s to enter the lock state, in which
case, no other buttons will respond i f p r e s s e d . Press them again
together for 5 secs to exit the mode.
If there is a preference for °F rather than °C (default), under OFF state press
and hold MODE and decrease temp. set point buttons together for 5 secs.
Under t h e OFF state, the user can select the commissioning status by
pressing FUNCTION and TIMER for five secs. 00 appears on the temp. display
when MODE is pressed, then adjust the options shown in the timer area by
pressing
and . There are four options:
Indoor ambient temperature is sensed by the return air temperature
sensor ( 01 displayed on the timer area).
Indoor ambient temperature is sensed by the wired controller (02
Function+Timer
displayed on the timer area).
The return air temperature sensor is selected under the cooling, dry, or
fan mode; while the wired controller temperature sensor is selected under
the heating or auto mode (03 is displayed on the timer area).
The wired controller temperature sensor is selected under the cooling,
dry, or fan mode; while the return air temperature sensor is selected under
the heating mode. (04 is displayed on the timer display area).
Under t h e OFF state, users can access the commissioning status by
pressing FUNCTION and TIMER for five secs. Press MODE until "01"
Function+Timer
appears in the temperature display area. The setting status appears in the
timer area. Press and to adjust. The two options are:
Three low levels (01) ;
2
3
4
Mode
Fan
Timer
On/Off
6
7
F
u
n
t c
o i
n
60.8 F~
Three high levels (02).
3
8
o
o
o
o
86 F(16 C~30 C)
appears on the
appears on

Advertisement