CAC / BDP KSACN0201AAA Owner's Manual

Wired controller for high wall ductless systems

Advertisement

Quick Links

KSACN0201AAA
NOTE: Read the instruction manual before starting the installation.
SAFETY CONSIDERATIONS
Installing, starting up, and servicing air−conditioning equipment
can be hazardous due to system pressures, electrical components,
and equipment location (roofs, elevated structures, etc.).
Only trained, qualified installers and service mechanics should
install, start−up, and service this equipment.
Untrained personnel can perform basic maintenance functions such
as cleaning coils. All other operations should be performed by
trained service personnel.
When working on the equipment, observe precautions in the
literature and on tags, stickers, and labels attached to the
equipment.
Follow all safety codes. Wear safety glasses and work gloves. Keep
quenching cloth and fire extinguisher nearby when brazing. Use
care in handling, rigging, and setting bulky equipment.
Read these instructions thoroughly and follow all warnings or
cautions included in literature and attached to the unit. Consult
local building codes and National Electrical Code (NEC) for
special requirements. Recognize safety information.
This is the safety−alert symbol
the unit and in instructions or manuals, be alert to the potential for
personal injury. Understand these signal words: DANGER,
WARNING, and CAUTION. These words are used with the
safety−alert symbol. DANGER identifies the most serious hazards
which will result in severe personal injury or death. WARNING
signifies hazards which could result in personal injury or death.
CAUTION is used to identify unsafe practices which may result in
minor personal injury or product and property damage. NOTE is
used to highlight suggestions which will result in enhanced
installation, reliability, or operation.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF
position. There may be more than 1 disconnect switch.
Lock out and tag switch with a suitable warning label.
Owner's Manual
! !
. When you see this symbol on
High Wall Ductless Systems
WARNING
!
ELECTRICAL DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage or improper operation.
Do not install the wired controller in an area subjected
to excessive steam, oil or sulfide gas. Doing so may
cause the controller to to deform and/or fail.
AUTO TURBO
SHIELD MEMORY MASTER SAVE
Enter/Cancel
Enter/cancel
Function
Fig. 1 - Wired Controller
TABLE OF CONTENTS
SAFETY CONSIDERATIONS
WIRED REMOTE CONTROLLER
LCD DISPLAY ICON DESCRIPTIONS
WIRED REMOTE CONTROLLER BUTTONS
OPERATION INSTRUCTIONS
INSTALLATION AND DISASSEMBLY
Wired Controller for
F
SET
HOUR
A
CO
QUIET
U
E-HEATER
BLOW
2
T
O
Mode
Fan
Timer
On/Off
PAGE
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
1
2
2
3
4
8

Advertisement

Table of Contents
loading

Summary of Contents for CAC / BDP KSACN0201AAA

  • Page 1 KSACN0201AAA Wired Controller for High Wall Ductless Systems Owner's Manual NOTE: Read the instruction manual before starting the installation. SAFETY CONSIDERATIONS WARNING Installing, starting up, and servicing air−conditioning equipment can be hazardous due to system pressures, electrical components, ELECTRICAL DAMAGE HAZARD and equipment location (roofs, elevated structures, etc.).
  • Page 2: Wired Remote Controller

    WIRED REMOTE CONTROLLER WIRED REMOTE CONTROLLER LCD DISPLAY AUTO TURBO HOUR SHIELD MEMORY MASTER SAVE E-HEATER BLOW QUIET Mode Enter/Cancel Enter/cancel Fig. 3 - LCD Display Function Timer On/Off Fig. 2 - Wired Remote Controller LCD DISPLAY ICON DESCRIPTIONS Table 1—Icon Descriptions Symbols Description Swing function...
  • Page 3 WIRED REMOTE CONTROLLER BUTTONS Mode Enter/Cancel Enter/cancel Function Timer On/Off Fig. 4 - Wired Remote Controller Buttons WIRED REMOTE CONTROLLER BUTTON FUNCTIONS Table 2—Controller Button Functions Name Function Enter/Cancel Function selection and cancellation ° ° ° ° Running temp. setting of the indoor unit, range: 60.8 F~86 F (16 C~30...
  • Page 4: Temperature Setting

    OPERATION INSTRUCTIONS ON/OFF TEMPERATURE SETTING Press ON/OFF to turn on the unit. Press ON/OFF again to turn it off. Press to increase or decrease the temperature. If these NOTE: Fig.5 displays the unit’s OFF state after power on. Fig.6 buttons are pressed continuously, the temperature either increases displays the unit’s ON state after power on.
  • Page 5: Timer Setting

    TIMER SETTING Under the ON/OFF state, press TIMER to set TIMER OFF/ON. TIMER OFF mode: Press TIMER, if LCD does not display xx.x hour, it means the timer setting was cancelled TIMER ON mode: Press TIMER and the LCD displays (Fig.
  • Page 6: Sleep Mode

    SWING MODE SWING ON: Press FUNCTION under the unit’s ON state SWING OFF: When the SWING function is on, press to activate the SWING function and blinks. Next, press FUNCTION to enter the SWING setting interface . Next, ENTER/CANCEL to confirm. press ENTER/CANCEL to cancel the function (see Fig.
  • Page 7: Turbo Setting

    TURBO SETTING When the TURBO function is activated, press FUNCTION to TURBO: The unit on the high fan speed generates quick enter the TURBO mode and then press ENTER/CANCEL to cooling or heating so the room temperature can quickly cancel (see Fig. 15). approach the setting value.
  • Page 8: Installation And Disassembly

    OTHER FUNCTIONS INSTALLATION AND DISASSEMBLY 1. LOCK: Upon start−up, without malfunction or under the CONNECTION TO THE HIGH WALL INDOOR unit’s “OFF” state, press at the same time for 5 UNIT: seconds until the wired remote controller enters the LOCK Consult the installation instructions of each indoor unit for proper installation.
  • Page 9 Figure 18 displays the wired remote controller installation steps. NOTE: There are several issues that require the installer’s attention. 1. Prior to the installation, cut off the power supply to the wire buried in the installation hole. 2. Remove the four−core twisted pair line from the installation holes and run them through the rectangular hole behind the wired remote controller plate.
  • Page 10: Error Display

    PG motor zero-crossing protection Catalog No:KSACN0201AAA-02OM Copyright 2017 CAC / BDP D 7310 W. Morris St. D Indianapolis, IN 46231 Edition Date: 08/17 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Table of Contents