Troubleshooting Guide - Health Zenith 4114 Installation And Operating Instructions Manual

Motion-activated coach light
Table of Contents

Advertisement

Available languages

Available languages

SYMPTOM
POSSIBLE CAUSE
Lights will not
1. Light switch is turned off.
come on.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Sensor not detecting movement.
6. Incorrect circuit wiring, if this is a new installation.
Lights come on in
1. Light control may be installed in a relatively dark
daylight.
location.
2. Light control is in TEST.
Lights come on for
1. Light control may be sensing small animals or automobile
no apparent reason.
traffic.
2. Sensitivity is set too high.
Lights stay on
1. The sensor may be picking up a heat source like an air
continuously.
vent, dryer vent, or brightly painted, heat-reflective
surface.
2. Light control is in Manual Mode.
3. Sensitivity is set too high.
Lights flash on
1. Light control is in the TEST mode and warming up.
and off.
2. Heat being reflected from other objects may be affecting
the sensor.

TROUBLESHOOTING GUIDE

8
SOLUTION
1. Turn light switch on.
2. Check lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Increase sensitivity.
6. Verify wiring is correct.
1. The fixture is operating normally under these
conditions.
2. Set control switch to 1, 5, or 10 minutes.
1. Reduce sensitivity.
2. Reduce sensitivity.
1. Reduce sensitivity.
2. Switch to Auto.
3. Reduce sensitivity.
1. Flashing is normal under these conditions.
2. Reduce sensitivity.
206873-02

Advertisement

Table of Contents
loading

Related Products for Health Zenith 4114

Table of Contents