Specifications - Health Zenith 4114 Installation And Operating Instructions Manual

Motion-activated coach light
Table of Contents

Advertisement

Available languages

Available languages

MODE SWITCHING SUMMARY
TEST
ON-TIME Switch at 1, 5, or 10
minutes
AUTO
MANUAL MODE
* If you get confused while switching modes, turn
the power off for one minute, then back on. After
the calibration time the control will be in the AUTO
mode.
Range .................................................Up to 30 ft. (9.1 m) [varies with surrounding temperature]
Sensing Angle.....................................Up to 150°
Electrical Load ...................................Up to 60 Watt Maximum Incandescent
Bulb Type ...........................................Medium Base, Type "A", 60 Watt Maximum
Sensor Capacity ..................................Up to 500 Watt (4.1 A) Maximum
Power Requirements ...........................120 VAC, 60 Hz
Operating Modes ...............................TEST, AUTO, and MANUAL MODE
ON-Timer ..........................................1, 5, 10 minutes
Test Timer ..........................................5 Seconds
Manual Mode Timer ..........................Dusk-to-Dawn
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
CAN ICES-3 (B)/NMB-3(B)
206873-02
Flip light switch off for
one second then back
on*

SPECIFICATIONS

ADJUSTMENT OF COVERAGE AREA
The sensor on this light fixture detects "motion"
by the movement of heat across the coverage
area. However, following are examples of objects
that also produce heat and can cause the sensor
to trigger:
• Pools of Water
• Dryer Vents
• Heating Vents
If you suspect that a heat source of this type is
triggering the sensor, reduce the sensitivity.
7
• Air Conditioners
• Animals
• Automobile Traffic