Harbor Freight Tools Vulcan Migmax 215 Owner's Manual & Safety Instructions page 10

Mig welding system
Table of Contents

Advertisement

12. DCEP Direct Current Electrode Positive Wire
Setup for Solid Core (gas shielded) welding:
a. Remove the two Wingnuts securing the
cables. Connect the Black Ground Cable to the
negative (
) Terminal using the Wingnut.
Connect the Red Cable to the positive (+)
Terminal using the other Wingnut.
Make sure the Cable connectors
sit flush in the grooves.
b. Determine which type of shielding gas
would be appropriate for the welding
you will do. Refer to the Settings Chart
on the inside of the Welder door.
c. With assistance, set the cylinder (not included)
onto a cabinet or cart near the Welder
and secure the cylinder in place with two
straps (not included) to prevent tipping.
d. Remove the cylinder's cap. Stand to the
side of the valve opening, then open the
valve briefly to blow dust and dirt from the
valve opening. Close the cylinder valve.
e. Locate the Regulator (included) and close its
valve until it is loose, then thread Regulator
onto cylinder and wrench tighten connection.
Note: When using C100 shielding gas, connect the
enclosed CGA 580/320 adapter to the inlet connection
of the Regulator and wrench tighten. Thread the
adapter onto the gas cylinder and wrench tighten.
f. Attach the Gas Hose (included) to the
Regulator's outlet and the Welder's gas
inlet. Wrench-tighten both connections.
Page 10
For technical questions, please call 1-888-380-0318.
DCEP
Solid Core (Gas Shielded) Polarity Setup
c
f
e
Power Input
Gas Inlet
Reset
Briefly open valve
d
to clean,
then close
valve.
Item 63617